Operation
Base Operation
Remote controller |
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while.
When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room | Designated | Timer | Fan | Operation | emergency |
operation switch | |||||
temperature | temperature | mode | speed | mode | Pi |
|
|
|
|
| |
Above 23oC | 26oC | No | AUTO | COOL |
|
Below 23oC | 23oC | No | AUTO | HEAT |
|
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
2.Select operation mode
COOL button:Cooling mode HEAT button: Heating mode DRY button: Dehumidify mode
3.Select temp.setting
Press |
| button | ||
| ||||
|
| Every time the button is pressed, temp.setting | ||
|
| increase 1oC,if kept depressed, it will increase | ||
|
| rapidly |
|
|
|
| Every time the button is pressed, temp.setting | ||
|
| |||
|
| decrease 1oC,if kept depressed, it will |
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16oC, do not use it in the normal operation.
Continue to press the test operation switch for more than 5 seconds . After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor unit will run in high speed.
test operation switch
Pi
Pi
decrease rapidly |
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
Display
circulated
LOW MED | HI | AUTO |
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation | Remote | Note | |
Mode | Controller | ||
| |||
|
| Under the mode of auto operation, air conditioner will | |
AUTO |
| automatically select Cool or Heat operation according to | |
| room temperature. When FAN is set to AUTO the air | ||
|
| conditioner automatically adjusts the fan speed according | |
|
| to room temperature. | |
COOL |
|
| |
DRY |
| In DRY mode, when room temperature becomes lower | |
| than temp.setting+2o C, unit will run intermittently at LOW | ||
|
| speed regardless of FAN setting. | |
|
| In HEAT mode, warm air will blow out after a short | |
HEAT |
| period of the time due to | |
| When FAN is set to AUTO, the air conditioner automatically | ||
|
| adjusts the fan speed according to room temperature. | |
|
| In FAN operation mode , the unit will not operate in COOL or | |
FAN |
| HEAT mode but only in FAN mode, AUTO is not available in | |
| FAN mode. And temp. setting is disabled. In FAN mode, | ||
|
| sleep operation is not available. |
Air Flow Direction Adjustment
1.Status display of air flow
Pos.1 Pos.2 Pos.3
Pos.4 Pos.5 Pos.6 (Auto swing)
cooling mode:from pos.1 to pos.4 and pos.6 heating mode:from pos.5 to pos.1 and pos.6
2.Left and right air flow adjustment(manual)
Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig.
'
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right.
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.