Operation
Timer On/Off On-Off Operation
1.After unit starts, select your desired operation mode. 2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
0.5h | 0.5h | 0.5h | 0.5h |
TIMER ON | TIMER OFF | TIMER | TIMER |
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER
3.Press / button to set time.
Press the button for each time, setting time in the first 12 hours increased by 0.5 hour every time, after 12 hours,increased by 1 hour every time.
Press the button for each time, settiing time in the first 12 hours decreased by 0.5 hour every time, after 12 hours,decreased by 1 hour every time.
It can be adjusted within 24 hours.
4.Confirm timer setting
After adjust the time,press button and confirm the
time ON or OFF button will not flash any more.
5.Cancel timer setting
Press the timer button by times until the time display eliminated.
Hints:
After replacing batteries or a power failure happens, time setting should be reset.
According to the Time setting sequence of TIMER ON or TIMER OFF, either
Healthy airflow Operation
1.Press to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations, to choose the swing location
what you needed,and then press button to confirm.
Healthy | Healthy | Present | |
airflow | airflow | ||
position | |||
upwarder | downwarder | ||
|
3.The cancel of the healthy airflow function
Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations again,and then press button to cancel.
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote controller.
Note:
1.After setting the healthy airflow function, the position grill is fixed.
2.In heating, it is better to select the mode. 3.In cooling, it is better to select the mode.
4.In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille .
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS
CE
All the products are in conformity with the following European provision:
-Low Voltage Directive 73/23/EEC
-Low Voltage Directive 2006/95/EC
ROHS
The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)
WEEE
In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the dis- posal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted
household waste. Do not try to dismantle the system yourself : the dismantling of the air
conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative cons- equences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and dis- posed of separately in accordance with relevant local and nationl legislation.
IMPORTANT INFORMATION REGA- RDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases |
|
covered by the Kyoto Protocol | A |
R410A | 1= | kg | B | |
2 | 1 | 2= | kg | C |
|
|
| ||
|
|
|
| |
|
| 1+2= | kg | D |
|
|
|
| |
F | E |
|
|
|
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant type:R410A
GWP* value:1975 GWP=global warming potential Please fill in with indelible ink,
•1 the factory refrigerant charge of the product
•2 the additional refrigerant amount charged in the field and
•1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover).
Acontains fluorinated greenhouse gases covered by the Kyoto Protocol
B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field
D total refrigerant charge E outdoor unit
F refrigerant cylinder and manifold for charging
4