3-Wire Cord Connections USA only

1.Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer in the upper corner.

2.Install a U.L. approved strain relief into the power cord entry hole of the mounting bracket. Finger tighten the nut only at this time.

3.Thread a U.L. Approved 30 Amp. Power cord, NEMA 10-30 Type SRDT, through the strain relief.

4.Attach the power cord neutral (center wire) conductor to the brass colored center terminal on the terminal block. Tighten the screw securely.

5.Attach the remaining two power cord outer conductors to the outer brass colored terminals on the terminal block. Tighten both screws securely. Warning: Do not make a sharp bend or crimp wiring/conductor at connections.

6.Reattach the strain relief mounting bracket to the back of the dryer with two screws. Tighten screws securely.

7.Tighten the screws securing the cord restraint firmly against the power cord.

8.Tighten the strain relief nut securely so that the strain relief does not turn.

9.Reinstall the terminal block cover.

Brass Terminal

Green Ground

Screw

Green Neutral

Ground Wire

tighten nut to

nut

strain relief

mounting bracket

these threads

power cord