English
4-Wire Cord Connections
Green Ground
Green Power Cord
Brass Terminal
Screw
Ground Wire
Terminal Block
Green Neutral
Ground Wire
Red
Power Cord
Strain Relief
Mounting Bracket
Black
Tighten Nut to
These Threads
Nut
1.Removethe screws securingthe terminal block accesscoverand the strain relief mounting bracketlocatedon the backof the dryer upper corner.
2.Install a UL approvedstrain relief into the power cord entry hole of the mounting bracket. Finger tighten the nut only at this time.
3.Removethe green neutral ground wire from the green ground screw located abovethe terminal block.
TypicalConductor
Receptacle
Black 240V
White Neutral
Typical4
Red 240V
ConductorCord
Green Ground