INSTALLATION
OPTIONAL WALL | OPTIONAL REMOTE |
THERMOSTAT | CONTROL |
FINAL CHECK
Before leaving this unit with the customer, the installer must ensure that the appliance is firing
A wall thermostat may be installed if desired, follow the wiring diagram below. FPI offers an optional programmable thermostat but any 250- 750 millivolt rated
Thermostat Wire Table
Recommended Maximum Lead Length
Thermostat
Wire Size | Max. Length |
14 GA. | 50 Ft. |
16 GA. | 32 Ft. |
18 GA. | 20 Ft. |
20 GA. | 12 Ft. |
22 GA. | 9 Ft. |
|
|
CAUTION
Do not connect the millivolt wall
thermostat wires to the 120V wires.
Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. Use Thermostat Wire Table.
2)Connect the wires as per the wiring dia- grams below.
CAUTION
Do not connect the millivolt
remote control wires for
to the 120V wires.
3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.
correctly. This includes:
1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) at 15 minutes.
2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.
3)Check for proper draft.
CAUTION
Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.
15 |