INSTALLATION
pass through the chimney above the appli- | mend using the Simpson |
ance. Move the appliance into the exact | (923GK adapter and 991 |
location where it is to be installed. Ensure |
|
that the Insert is level. | The Air Intake pipe must be attached to the inlet |
| air collar of the termination cap. |
Diagram 3
Note: A noncombustible mantel may be installed at a lower height if the framing is made of metal studs covered with a noncombustible board.
GAS CONNECTION
GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.
1)If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry or factory built fireplace.
2)The appliance is provided with an opening on the left hand side of the control compart- ment. A 3/8" NPT gas supply pipe must be brought near this inlet hole.
3)Locate the center point where the vent will
VENTING
THE APPLIANCE MUST NOT BE
CONNECTED TO A
CHIMNEY FLUE SERVING A
SEPARATE SOLID FUEL
BURNINGAPPLIANCE.
This appliance is designed to be attached to two 3" (76mm)
Masonry chimneys may take various contours which the flexible liner will accommodate. How- ever, keep the flexible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Part # Description
Alternate Approved Caps
980 | Vertical Termination Cap |
991** | High Wind Cap |
923GK** | 3" |
*Recommended for installations up to and in- cluding 25 ft. (7.6m) in length/height.
**For installations in excess of 25 ft. (7.6m) or in areas of consistently high winds, we recom-
FLUE LINER
INSTALLATION
1)Cut the flex liner as required.
2)Mark the end of one liner to indicate Inlet.
3)Connect the other end of the above liner to the inlet side of the termination adaptor, seal connection with high temperature silicone. Secure with gear clamp.
4)Connect the 2nd liner to the exhaust side of the adaptor, seal connection with high tem- perature silicone. Secure with gear clamp.
5)Install flashing.
6)Insert both liners into chimney, passing through the damper opening.
7)Install termination cap.
8)Connect the marked end of the liner to the inlet collar of the vent connector plate marked with an "I", seal connection with high temperature silicone. Secure with gear clamp.
7 |