6.If you are using an extension cord outdoors, make sure it is marked with the suf- fix
7.Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified elec- trician before using it.
8.Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
|
|
| (120 VOLT) |
|
|
|
| |
|
|
|
|
|
| |||
NAMEPLATE |
| EXTENSION CORD LENGTH |
| |||||
AMPERES |
|
|
|
|
|
|
| |
(At Full Load) |
|
|
|
|
|
|
| |
|
| 25 | 50 |
| 75 |
| 100 | 150 |
|
| Feet | Feet |
| Feet |
| Feet | Feet |
0 – 2.0 | 18 | 18 |
| 18 |
| 18 | 16 | |
2.1 | – 3.4 | 18 | 18 |
| 18 |
| 16 | 14 |
3.5 | – 5.0 | 18 | 18 |
| 16 |
| 14 | 12 |
5.1 | – 7.0 | 18 | 16 |
| 14 |
| 12 | 10 |
7.1 – 12.0 | 18 | 14 |
| 12 |
| 10 | - | |
12.1 | – 16.0 | 14 | 12 |
| 10 |
| - | - |
16.1 | – 20.0 | 12 | 10 |
| - |
| - | - |
FIGURE C | * Based on limiting the line voltage drop |
|
|
to five volts at 150% of the rated amperes.