RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOLT)
NAMEPLATE |
| EXTENSION CORD LENGTH |
| ||||
AMPERES |
|
| |||||
|
|
|
|
| |||
(at full load) |
|
|
|
|
| ||
25 Feet | 50 Feet | 75 Feet | 100 Feet | 150 Feet | |||
|
| ||||||
0 – 2.0 | 18 | 18 | 18 | 18 | 16 | ||
2.1 | – 3.4 | 18 | 18 | 18 | 16 | 14 | |
3.5 | – 5.0 | 18 | 18 | 16 | 14 | 12 | |
5.1 | – 7.0 | 18 | 16 | 14 | 12 | 12 | |
7.1 – 12.0 | 18 | 14 | 12 | 10 | - | ||
12.1 | – 16.0 | 14 | 12 | 10 | - | - | |
16.1 | – 20.0 | 12 | 10 | - | - | - |
TABLE A * Based on limiting the line voltage drop to five volts at 150% of the rated amperes.
Symbology
|
|
| Double Insulated | V~ | Volts Alternating Current | |
|
|
| ||||
|
|
|
|
|
|
|
|
|
| Canadian Standards Association | A | Amperes | |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| Underwriters Laboratories, Inc. | n0 xxxx/min. | No Load Revolutions per Minute | |
|
|
| (RPM) | |||
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
| SPECIFICATIONS |
| |
|
|
| ||||
|
|
| ||||
Electrical Requirements | 120 V~ / 60 Hz / 16 Amps |
| ||||
|
|
|
| 1 HP Single Phase Motor / 1720 RPM | ||
|
|
|
| Power Switch Type: Toggle |
| |
|
|
|
| Circuit Breaker: 18 Amps (Resettable) | ||
|
|
|
| Power Cord Type: 14 AWG x 3C | ||
|
|
|
| Plug Type: 120 Volt / | ||
Stock Capacity at 90° | 7” (Round) / 7” x 12” (Rectangle) | |||||
Blade Speeds | 90 FPM / 135 FPM / 195 FPM / 255 FPM | |||||
(Feet Per Minute) |
|
|
| |||
Blade Size | 0.75” x 0.031” x 93” (Carbon Steel Blade) | |||||
Teeth Per Inch | 6 TPI |
|
| |||
Belt Type |
|
| ||||
Miter Slot Width / Depth | 11/16” Wide / 9/16” Deep |
| ||||
Hydraulic Ram Travel |
|
| ||||
Base Mounting Holes | 3/8” Diameter (Qty. 4) |
| ||||
Wheel Dimensions | 5” Diameter x 1” Wide |
|
SKU 97009 | For technical questions, please call | Page 10 |