Venting
P38+ Pellet Stove
Fig. 12
Fig. 13
#6 Installing into an existing fireplace
chimney ( US and Canada )
This method provides excellent venting for normal op- eration. This method also provides natural draft in the event of a power failure.
In Canada and some places in the US it is required that the vent pipe extend all the way to the top of the chimney.
In this method a cap should also be installed on the chimney to keep out rain. Be sure to use approved pellet vent pipe fittings. Seal pipe joints with silicone in addition to the sealing system used by the manufacturer. Pipe size should be increased to 4" using this method.
#7 Installing into an existing chimney
( US and Canada )
This method provides excellent venting for normal op- eration. This method also provides natural draft in the event of a power failure.
In Canada and some places in the US it is required that the vent pipe extend all the way to the top of the chimney. The pipe or liner inside the chimney should be 4"diameter.
In this method a cap should also be installed on the chimney to keep out rain. One disadvantage of this method is that it is harder to clean the vent pipe, therefore, there is a tendancy not to do it as often as needed.
12