Installation
P38+ Pellet Stove
Place the stove on a noncombustible floor protector that extends 6 inches to the front, 6 inches to the sides and 1 inch to the rear of the stove. The minimum floor protector material is 24 gauge sheet metal.
Place the stove away from combustible walls at least as far as shown in figures 3,4 and 5. Please note the difference in side wall clearance with and without side shields.
Note that the clearances shown are minimum for safety but do not leave much room for access when cleaning or servicing. Please take this into account when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz grounded receptacle. (A surge protector is recommened to protect the circuit board).
Prior to installing flue pipe, connect a draft meter to the stove as shown in fig. 6 . (The draft meter must have a mini- mum range of
.15" cold. Allow combustion blower to operate for approxi- mately 1 minute before recording or adjusting low draft.). See page 19 for low draft adjustment procedures.
After connecting the flue system, follow the above pro- cedure. However, prior to taking the draft reading be sure all doors and windows in the home are closed. Record the draft reading_______. If this reading is more than .05" lower than
the unconnected reading, check for possible restrictions or the need for outside air (see page 7).
Mobile Home Installation
When installing this unit in a mobile home several require- ments must be followed:
1.The unit must be bolted to the floor. This can be done with 1/4" lag screws through the 2 holes in the base plate.
2.The unit must also be connected for the outside air. See
page 8.
3.Floor protection and clearances must be followed as
shown.
4.Unit must be grounded to the metal frame of the mobile
home.
CAUTION: This appliance must be vented to the outside.
Mobile home installation should be done in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24.
CAUTION
The stove is hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.
6
2" |
2" |
Fig. 3 |
1" | 2" |
|
6" | 6" | Side Shields |
| 10" | |
| 6" | With |
|
| |
FLOOR PROTECTOR |
| |
| Fig. 4 |
|
| 16" | Side Shields |
| Without | |
FLOOR PROTECTOR |
| |
Fig. 5 |
|
|
Fig. 6