C. Junction Box Installation
|
| INSERT STRAIN RELIEF |
|
| AROUND CORD IN THIS END |
FEED PLUG |
| FROM OUTSIDE OF UNIT |
|
| |
THROUGH HOLE | SIDEWALL | |
|
| |
JUNCTION |
| |
BOX |
| |
| SCREW |
|
| PROVIDED |
|
Figure 10.3 | Junction box installation |
|
Optional Accessories
Connecting the electrical junction box is required if using a blower or remote.
•Plug the cord into a convenient outlet.
•Must use cord supplied.
WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.
D. Fan Replacement
On units already installed removal of decorative front, surround and gas insert is required.
•Detach flexible liner from back of unit if insert is in- stalled.
•Remove the four screws on the cover plate (see Figure 10.4).
| FAN | COVER |
|
| PLATE |
POWER | GROUND |
|
WIRE |
| |
CORD |
|
|
Figure 10.4 |
|
|
•Remove the old fan. See Figure 10.5.
•Place the new fan in between the bend up tabs.
•Install and wire the fan per instruction shipped with the fan.
•The ground wire of the fan can clip on the side of the base pan.
•Reinstall the cover plate back on the unit. Make sure the fan does not make contact with the back wall to prevent noise from vibration.