8 Installing Vent Pipe and Appliance
A. Vent Limits
The abbreviations listed in this vent table key are used in the vent diagrams.
Description
Minimum Vertical Run Length 14 ft.
Maximum Vertical Run Length 50 ft.
Horizontal venting is NOT allowed.
Vertical terminations are measured to top of chimney.
This appliance is listed for use with
WARNING! Risk of Fire/Explosion/Asphyxiation! Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.
•May impair safe operation of this appliance or other appliances connected to the flue.
•Vent this appliance directly outside.
•Use separate vent system for this appliance.
CAUTION! ALL vent specifications MUST be followed. This product is tested and listed to these specifications. Appliance performance will suffer if specifications are not followed.
B. Venting Components
CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.
The vertical vent termination system installed on this model includes:
•One
•Flexible vent pipe for exhaust air (included with vent kit).
•One length of
•One
•One vertical termination cap (included with vent kit).
C. Connecting Vent Pipe
Reference instructions in the termination kit.
•Install the
•Secure the exhaust flexible vent pipe to the 3 foot section stainless steel flexible vent pipe using the factory- installed
•Use 3 screws to attach either a 4 foot or 30 foot section of inlet air vent to the inlet collar on the collar slide plate (see Figure 8.1). NOTE: The collar slide plate may be removed from appliance to aid installation.
Note: To achieve optimum performance of insert, minimize or avoid bends in exhaust vent pipe.
TERMINATION
CAP
ADAPTOR
EXHAUST COLLAR
INLET AIR COLLAR
EXHAUST
VENT PIPE
V= 14 FT. MINIMUM 50 FT. MAXIMUM
3 INCH COLLAR
(Factory installed to
stainless steel section)
WARNING: DO NOT
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
SEALING MATERIAL
STAINLESS STEEL
PIPE - 3 FT. MIN.
REQUIRED (INCLUDED)
INLET AIR
VENT PIPE
COLLAR ATTACHMENT
BRACKET
Figure 8.1