Installation13
7.If the room sensor is used as a return air sensor rather than a room thermostat/sensor, the black cable will not be used. The room sensor itself (gray cable with black and red wires) will be connected to the blue twisted wires from the control board.
Note: The stove body must be able to slide out of the shell to the limit of the power cord wires for cleaning and service. Therefore, if the room sensor is connected as a return air sensor, the wire should be connected long enough to allow this, but not too long that it would get tangled or pinched anywhere.
Notice: The male/female connections between the mounting shell and the stove body should always be maintained. Wirenut or taped splices should never be used.
Connecting the room sensor as a return airsensor
•Insert the sensor end of the wire from the rear of the mounting frame through the hole as shown in fig. 24 .
•Tyrap the sensor end so that the sensing tip is in the middle of the front return air opening. See Fig. 25.
•Tyrap the sensor wire to the inside of the mounting frame up to the cord grounding location. Follow the power wiring to where you make the male/female ter- minal connection to the twisted blue wires.
There are (2)
Fig. 24
8.Install the (4)
1/2" threaded wedging rods
(5) bolt down holes | 3/8 x 16 tapped | |
leveling bolt holes | ||
| ||
| Fig. 26 |
Fig. 25 | Side Return Air Holes |