Low Draft Voltage Adjustment

19

 

 

After the installation is completed but before the first fire is lit, check and record the high and low draft readings.

Combustion Motor Speed Control

Low draft only set point.

The small straight screwdriver slot is plastic; therefore, the unit can be adjusted while in operation.

Fig.44

These units are pre-tested at the factory with exactly 120 Volts A.C., 60 Hz. They are checked and adjusted for firebox tightness, gasket leakage, motor operation and igniter operation. The stove is then factory set at a high adjustment. NOTE: Low draft adjustment maybe required. The factorylow draft setting maynot be correct for the units permanent installation conditions.

The control board on the Accentra Insert is equipped with a low draft adjustment port. Located on the control face just to the right of the igniter light. See Figure 44. This voltage adjustment is provided to allow the unit to be adjusted for the household voltage where the unit is going to be in permanant operation. NOTE: The line voltage varies from area to area and often home to home.

The low draft voltage should be adjusted to achieve the most efficient burn on low burn or "maintenance". This voltage adjustment allows the installer to change the low voltage set point approximately 15 volts. This adjustment should be done by the installer during set up because a draft meter reading is required to insure proper set up.

If the unit is not adjusted properly, it does not cause a safety concern. If the unit is adjusted too high, only effiency is lost. If the unit is adjusted too low, the low draft pressure switch will not allow the feeder motor or the igniter to operate.

Fig. 45

Draft Meter bolt hole location

The head of the plug bolt can be accessed through the bottom distribution air inlet with the cast ash lip removed.

A simple draft test should be performed after completing the flue pipe installation. To record the results for future reference:

1.Plug unit into a 120VAC, 60 HZ outlet.

2.Close the hopper lid and front view door. Neither pellets or a fire are required for this test.

3.With the mode selector in the "OFF" position, turn the feed adjuster to "TEST".

4.Record the high draft_____in. W.C. (Normal is -

.45 to -.55) The control will be on the High Draft for a total of 2 minutes.

5.After 2 minutes is up, the combustion motor will go down to low draft and the distribution blower will go on high. Allow approximately 15 seconds to pass for the combustion motor to slow before checking the low draft.

6.If the low draft is between .30 and .35, record the reading _____ in. W.C. If the reading is higher, slowly turn the set screw counter-clockwise until the draft lowers. If the reading is lower, very slowly turn the set screw clockwise until the draft increases.

NOTE:The test mode alternates from high to low draft every 60 seconds. If more time is needed for draft adjustment, wait until the next low draft cycle.

NOTE: In some cases, the draft may not go as low as .30 even with the set screw completely counter-clockwise.

Page 18
Image 18
Harman Stove Company The Harman Accentra Pellet Insert manual Low Draft Voltage Adjustment, Draft Meter bolt hole location

The Harman Accentra Pellet Insert specifications

The Harman Stove Company is renowned for its high-quality heating solutions, and the Harman Accentra Pellet Insert exemplifies their commitment to efficiency and performance. Designed to seamlessly blend into existing fireplace openings, the Accentra Pellet Insert offers homeowners a reliable source of warmth while enhancing the aesthetics of their living space.

One of the standout features of the Accentra is its advanced pellet-burning technology. This insert utilizes a powerful feed system that ensures a consistent and controllable burn rate, leading to a more efficient heating experience. The patented Smart Control technology enables users to monitor and adjust the temperature easily, ensuring that every room is kept at the perfect temperature with minimal effort.

The Accentra Pellet Insert also comes equipped with a user-friendly interface, making it accessible even for those unfamiliar with pellet stoves. Its LCD screen displays vital information, including temperature settings and fuel levels, allowing users to make informed adjustments. This level of convenience is complemented by the unit's automatic ignition feature, which simplifies startup, eliminating the need for matches or manual lighting.

In terms of efficiency, the Harman Accentra boasts an impressive high-efficiency rating. With a heating capacity of up to 2,200 square feet, it provides substantial warmth, making it an ideal choice for larger homes or open spaces. The insert’s environmentally-friendly design minimizes emissions, contributing to cleaner air and promoting sustainable heating practices.

The construction of the Accentra Pellet Insert is equally impressive. Built with durable materials, it is designed for longevity and dependability. The insert's sleek and contemporary design fits neatly into a variety of home decors, allowing homeowners to enjoy a cozy fire without sacrificing style.

Another key characteristic of the Accentra Pellet Insert is its versatility in fuel options. Users can choose from various brands of pellets, optimizing fuel choices based on availability and pricing. With a large capacity hopper, the Accentra can hold ample pellets, reducing the frequency of refueling and allowing for extended burn times.

In summary, the Harman Accentra Pellet Insert embodies the company's dedication to quality and innovation. With its efficient heating capabilities, advanced technology, user-centric design, and adaptability, it stands out as a premium choice for anyone looking to enhance their home’s heating system while enjoying the comforting glow of a real fire. Investing in the Harman Accentra is not just a choice for warmth; it's a commitment to quality, aesthetics, and sustainable living.