Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Tempered Glass Specifications . . . . . . . . . . . . . . . . . . . . . 7 C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 7 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 7 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 C. Fan Kit (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 E. Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . . 10 F. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 G. Remote Controls, Wall Controls and Wall Switches. . . . . 10 H. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 10 I. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 11 J. After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 K. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 12

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 13 B. Maintenance Tasks-Qualified Service Technician . . . . . . 14

Installer Guide

4 Getting Started

A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 16

B. Design and Installation Considerations . . . . . . . . . . . . . . 17

C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 17

D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 17

5 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . 18

B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . 19

C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

D. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 20

6 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 21

7 Vent Information and Diagrams

A. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

B. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

C. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

D. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 33 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 33 C. Install the Ceiling Firestop . . . . . . . . . . . . . . . . . . . . . . . . 34 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 35 E. Installing the Optional Heat-Zone-Gas Kit . . . . . . . . . . . . 35

9 Appliance Preparation

A. Choosing the Top or Rear Vent . . . . . . . . . . . . . . . . . . . . 36 B. Rear Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C. Installing the Non-combustible Board. . . . . . . . . . . . . . . . 37 D. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 37

10 Installing Vent Pipe (DVP and SLP Pipe)

A. Assemble Vent Sections (DVP Pipe Only) . . . . . . . . . . . . 38 B. Assemble Vent Sections (SLP Pipe Only) . . . . . . . . . . . . 39 C. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 39 D. Secure the Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . 40 E. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 40 F. Install Decorative Ceiling Components (SLP only). . . . . . 41 G. Install Metal Roof Flashing. . . . . . . . . . . . . . . . . . . . . . . . 42 H. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 42 I. Install RF4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 J. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 44 K. Install Decorative Wall Components (SLP only). . . . . . . . 44 L. Heat Shield Requirements for Horizontal Termination . . . 44 M. Install Horizontal Termination Cap (DVP and SLP Pipe) . 45

11 Gas Information

A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 46

12 Electrical Information

A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 B. Intellifire Ignition System Wiring . . . . . . . . . . . . . . . . . . . . 47 C. Optional Accessories Requirements . . . . . . . . . . . . . . . . 47 D. Electrical Service and Repair . . . . . . . . . . . . . . . . . . . . . . 48 E. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 49 F. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 49

Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S2102-900 Rev. O • 12/08

3

Page 3
Image 3
Hearth and Home Technologies 6000GL-IPI-R, 6000GL-IPILP-R, 6000GL-IPILP-S, 6000GL-IPI-S Table of Contents, User Guide

6000GL-IPILP-S, 6000GL-IPI-R, 6000GL-IPILP-R, 6000GL-IPI-S specifications

Hearth and Home Technologies has consistently set the benchmark for innovation and efficiency in the realm of gas fireplaces. Among their notable offerings, the models 6000GL-IPI-S, 6000GL-IPILP-R, 6000GL-IPI-R, and 6000GL-IPILP-S stand out for their superior design and advanced technologies. These models cater to diverse homeowner needs, combining aesthetic appeal with functionality.

A defining feature of the 6000GL series is the advanced IntelliFireā„¢ Ignition System. This patented technology ensures a safe and efficient startup and operation, minimizing energy consumption while maximizing user convenience. With this system, users can enjoy a worry-free experience, as the ignition system is designed to only operate when needed.

Another significant characteristic of these models is their customizable options. Homeowners can choose linear and modern designs, along with various media options, including glass and stone, to create a personalized look that complements their space. The ability to customize not only enhances the beauty of the fireplaces but also allows for harmonious integration into various interior designs.

The 6000GL-IPI-S and 6000GL-IPILP-S models focus on direct vent technology, allowing for safe venting of exhaust gases without compromising indoor air quality. This is particularly beneficial in modern homes with tight construction. The models require minimal clearance, making them ideal for both new constructions and remodels.

For those who wish to enjoy a more traditional style, the 6000GL-IPI-R and 6000GL-IPILP-R models present a refined aesthetic, boasting classic fireplace elements that enhance any living space. These options engage viewers with a captivating flame pattern, producing realistic flickering flames that create an inviting atmosphere.

Moreover, Hearth and Home Technologies have incorporated energy-efficient features in these models. The fans operate quietly and efficiently, distributing heat more evenly throughout the room, thus ensuring a comfortable environment without the usual noise disturbances associated with traditional heating methods.

In summary, the Hearth and Home Technologies 6000GL-IPI-S, 6000GL-IPILP-R, 6000GL-IPI-R, and 6000GL-IPILP-S models exemplify the perfect blend of cutting-edge technology and timeless beauty. With customizable aesthetics, advanced ignition systems, direct vent capabilities, and energy-efficient performance, these fireplaces not only enhance home ambiance but also provide reliable heating solutions. Whether it's a modern or traditional setting, these models are sure to impress homeowners while delivering quality and comfort.