Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/0848
D. Electrical Service and RepairWARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Note: Appliance will not operate
unless properly grounded.
PLUG-IN
3VTRANSFORMER
ON/OFF
WALLSWITCH
IGNITION
MODULE
(3V)
VALVE
NEUTRAL GROUND
LOWVOLTAGE
SEENOTE 1
REMOTE
CONTROL HOT
PLUG-IN
REMOTE
JUMPERWIRE
ORG
GRN
BRN
BRN
RED
BLK
INTERMITTENT
PILOTIGNITOR
ORG
WHT
IGNITION MODULE 3 VAC
TRANSFORMER
VALVE
3 VAC
THERMOSTAT
WIRE
ASSEMBLY
BLACKWIRE CAN BE
PLUGGEDINTOANY
OF#1 - #5 LOCATIONS
ONTHE HOT SIDE
WHITEWIRE CAN BE
PLUGGEDINTO ANY
OF#1 -#5 LOCATIONS
ONTHE NEUTR AL SIDE
GROUNDTO
FIREPLACE
CHASSIS*