Top Vent - Horizontal Termination - (continued) Three Elbows
1
25
62
62
Download
62 pages, 3.51 Mb
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08
25
Figure 7.5
Top Vent - Horizontal Termination - (continued)
Three Elbows
H
2
H
1
V
2
V
1
V
1
Min.
H
1
Max.
V
2
Min.
H
2
Max.
V
1
+ V
2
Min.
H
1
+ H
2
Max.
1 ft.
305 mm
3 ft.
914 mm
1 ft.
305 mm
3 ft.
914 mm
2 ft.
610 mm
6 ft.
1.8 m
2 ft.
610 mm
6 ft.
1.8 m
2 ft.
610 mm
6 ft.
1.8 m
4 ft.
1.2 m
12 ft.
3.7 m
3 ft.
914 mm
9 ft.
2.7 m
3 ft.
914 mm
9 ft.
2.7 m
6 ft.
1.8 m
18 ft.
5.5 m
H
1
+ H
2
= 20 ft. (6.1 m) Max. V
1
+ V
2
+ H
1
+ H
2
= 50 ft. (15.2 m) Max. V
1
= 1 ft. (305 mm) Min.
Contents
Main
Owners Manual
NOTICE
DO NOT DISCARD
Models: 8000CF-OAK-IPI 8000CFLP-OAKIPI
Listing Label Information/Location
A. Congratulations
Homeowner Reference Information
Safety Alert Key:
Table of Contents
1 Listing and Code Approvals
User Guide
2 Operating Instructions
3 Maintenance and Service
Page
B. Limited Lifetime Warranty Hearth & Home Technologies LIMITED WARRANTY
B. Limited Lifetime Warranty (continued)
1
B. Tempered Glass Speci cations
C. BTU Speci cations
A. Appliance Certi cation
E. Non-Combustible Materials Speci cation
1
H. Requirements for the Commonwealth of Massachusetts
2
User Guide
2
B. Your Fireplace
A. Gas Fireplace Safety
D. Clear Space
C. Fan Kit (optional)
F. Fixed Glass Assembly
E. Decorative Doors and Fronts
G. Remote Controls, Wall Controls and Wall Switches
CAUTION:
NOT FOR USE WITH SOLID FUEL
WARNING:
DO NOT CONNECT 110 VAC TO THE CONTROL VALVE.
J. After Fireplace is Lit
K. Frequently Asked Questions
3
Glass Cleaning
3
A. Maintenance Tasks-Homeowner
Doors, Surrounds, Fronts
Remote Control
Venting
B. Maintenance Tasks-Quali ed Service Technician
Gasket Seal and Glass Assembly Inspection
Logs
Firebox
Page
4
A. Typical Appliance System
Figure 4.1 Typical System
Installer Guide
B. Design and Installation Considerations
D. Inspect Appliance and Components
C. Tools and Supplies Needed
5
A. Selecting Appliance Location
B. Constructing the Appliance Chase
C. Clearances
D. Mantel and Wall Projections
6
A. Vent Termination Minimum Clearances
6
V = VENT TERMINAL X
Covered Alcove Applications
7
A. Approved Pipe
C. Use of Elbows
7
B. Vent Table Key
D. Measuring Standards
H
H
One Elbow
E. Vent Diagrams
Two Elbows
Top Vent - Horizontal Termination
Heat & Glo 8000CF-OAK-IPI 2059-900 Rev. Q 11/08 25
Top Vent - Horizontal Termination - (continued) Three Elbows
H
V
H
V
Top Vent - Vertical Termination No Elbow
V1 = 50 ft. Max. (15.2 m) V1 = 3 ft. Min. (914 mm)
Installing the ue restrictor
BREAK HERE
Two Elbows
Three Elbows
Top Vent - Vertical Termination - (continued)
8
A. Pipe Clearances to Combustibles
8
B. Wall Penetration Framing
C. Install the Ceiling Firestop
D. Install Attic Insulation Shield
9
A. Attaching Sheetrock Ledges
B. Temporary Access Panel
C. Securing and Leveling the Appliance
D. Installing the Fiberglass Gasket
F. Checking Pilot Plate
E. Completing Grate Set-up
10
10
A. Assemble Vent Sections
A B
B. Assemble Slip Sections
C. Secure the Vent Sections
Page
E. Install Metal Roof Flashing
F. Assemble and Install Storm Collar
G. Install RF4-8
H. Install Vertical Termination Cap
I. Heat Shield Requirements for Horizontal Termination
J. Install Horizontal Termination Cap
11
A. Fuel Conversion
B. Gas Pressure
C. Gas Connection
11
12
12
D. Electrical Service and Repair
ORG
GRN
Figure 12.1 Intelli re Pilot Ignition (IPI) Wiring Diagram
BRN BRN
F. Wall Switch Installation for Fan (Optional)
E. Junction Box Installation
13
13
A. Mantel and Wall Projections
B. Facing Material
14
A. Remove Fixed Glass Assembly
B. Remove the Shipping Materials
C. Clean the Appliance
D. Accessories
G. Ember Placement
F. Install the Optional Refractory
Page
Page
M. Air Shutter Setting
I. Fixed Glass Assembly
Removing Fixed Glass Assembly
Replacing Fixed Glass Assembly
J. Install the Mesh
15
15
A. Intelli re Ignition System
Symptom Possible Cause Corrective Action
Intelli re Ignition System - (continued)
Symptom Possible Cause Corrective Action
16
16
A. Appliance Dimension Diagram
Heat & Glo 8000CF-OAK-IPI 2059-900 Rev. Q 11/08 55
B. Vent Components Diagrams
Figure 16.2 DVP vent components
DVP-TRAP1 DVP-TRAP2
DVP-TRAPK2 DVP-TRAPK1
Page
Page
Page
C. Service Parts List 8000CF-OAK-IPI
at Depot
Intermittent Pilot Ignition Valve Assembly
Service Parts
8000CF-OAK-IPI
at Depot
NOTICE