B. Install Fireplace & Chimney

Install as per Sections 7 and 8.

C. Install Chase Top

• You MUST use a chase top in a chase installation. Chase

tops are available from your Heatilator dealer or may be

field constructed.

• Include a turndown and drip edge to prevent water from

seeping into the chase.

• Include a 2 in. (51 mm) soldered, welded or spun collar

around pipe opening to keep water out.

• Provide a 1/8 in. (3 mm) gap around the flue pipe.

• Slope the chase top downward away from the

opening.

WARNING! DO NOT caulk the pipe to the chase top

collar. Restricting air flow around chimney may cause

fire.

• Caulk all seams to prevent leaks.

Slope Downward (1/4 in. per foot minimum)

2 in. (51 mm) Collar on Chase Top

Turn-down

Drip Edge

Chase

.018 (26 ga) min. Galvanized Chase Top

• Refer to Figure 9.3.

Figure 9.3 Chase Top Construction