INSTALLATION

1.Remove the knockout or cover plate from the top of the fireplace and discard it. See Figure 33.1.

2.Cut a 3 in. (76mm) hole in the insulation board as per the dimensions shown in Figure 33.1.

 

3-13/16 in.

 

 

 

 

(97mm)

 

 

 

3-1/8 in. (79mm)

 

 

 

 

C

Adapter

 

 

 

L

 

 

 

 

 

Mounting

 

 

 

 

Plate

 

 

 

 

Starter Pipe

 

 

Knockout

 

 

 

 

 

 

le

 

 

 

 

ho

 

 

 

.(76mm)

 

Cuta

3in

board

 

ininsulation

 

Figure 33.1

 

 

 

 

3.Determine the necessary length of starter pipe from the following table and cut as required. See Figure 33.2.

4.The starter pipe is shipped flat. After cutting to the required length, manually roll the pipe together and snap lock into place. NOTE: It is important the pipe length be adhered to or it will affect the performance of your fireplace.

Run Length

Cut Pipe

20

- 40 ft (6-12m)

2 in. (51mm)*

 

*A minimum of 2 in. (51mm) pipe must be used to

 

cover the raw insulation to prevent it tfrom blow-

 

ing out through the Return Air Grille.

10

- 20 ft (3 - 6m)

8 in. (203mm)

3

- 10 ft (1 - 3m)

No cut needed**

**Use full 16 in. (406mm) as supplied

Figure 33.2

Figure 33.3

6.Slide the starter pipe into the fireplace, matching the holes in the plate to the holes in the fireplace.

7. Place the Adapter on the Mounting Plate lining up holes. Using the 4 sheet metal screws included in the kit, secure the Adapter and Mounting Plate into fireplace. After secur- ing to the fireplace, tape down the Adapter edges to the top of the fireplace with aluminum tape to prevent leakage.

8.Determine the location for the air register and fan housing assembly. Cut a 7-5/8 in. x 13-5/8 in. (143 x 346mm) hole between framing members (wall studs or floor joists). The brackets can be rotated 180° and mounted to the back side of the 2 x 4 if necessary. See Figure 34.2 on page 34.

NOTE: The fan and electrical connections must be accessible for servicing per local code requirements.

NOTE: If the fan housing is installed in a 2 x 4 wall, the front of the housing will protrude approximately 1/4 in. (6mm) from the finished wall. See Figure 34.1 on page 34.

WARNING

Fire Risk

Comply with all minimum clearances speci- fied.

A minimum 1/2 in. (13mm) air clearance must be maintained at the back and 1 in. (25mm) to the sides of the fireplace assembly.

9.Attach enough 6 in. (152mm) B-Vent as required for your installation to the fan housing. A maximum of (4) 90° elbows is recommended. Securely twist lock the B-Vent to the Adapter.

Also screw the B-Vent to the outlet box on the fan housing. See Figure 34.2 on page 34. Support duct at intervals of no greater than 4 ft (1 m) as required by local code.

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 33

Page 33
Image 33
Hearth and Home Technologies C-40 warranty Run Length Cut Pipe Ft 6-12m, 20 ft 3 6m 10 ft 1 3m No cut needed

C-40 specifications

Hearth and Home Technologies (HHT) has long been known for its commitment to innovation and quality in the heating and home comfort industry. One of their standout offerings is the C-40, a versatile and efficient gas fireplace that embodies the brand’s dedication to modern aesthetics and advanced technology. This fireplace is designed to not only provide warmth but also enhance the ambiance of any living space.

The C-40 features a sleek, contemporary design that can seamlessly fit into various interior styles. Its clean lines and minimalist frame allow it to serve as a stylish focal point in a room, while offering the functionality and performance that homeowners expect from a high-quality gas fireplace. The unit is available in various configurations, including built-in and wall-mounted options, allowing for flexibility in installation and design.

One of the most notable features of the C-40 is its impressive heat output. With the ability to deliver efficient and evenly distributed warmth, this gas fireplace can effectively heat spaces of various sizes, making it an excellent choice for both small and large rooms. The adjustable flame height feature further enhances the user experience, allowing homeowners to customize their heating preference and create the perfect atmosphere for any occasion.

The C-40 is equipped with cutting-edge technologies, including electronic ignition and a remote control system, making it convenient and easy to use. The electronic ignition ensures quick and reliable startup, while the remote control allows for effortless temperature and flame adjustment from anywhere in the room. This added convenience is a significant benefit for those who value comfort and ease of operation.

Additionally, the C-40 incorporates advanced safety features, such as an automatic shut-off and a secure glass front, providing peace of mind for families. The glass front not only enhances safety but also serves to display the mesmerizing flames beautifully, allowing everyone to enjoy its warmth and glow.

In summary, Hearth and Home Technologies’ C-40 is a prime example of combining stylish design with modern technology and efficiency. Its exceptional heat output, customizable features, and advanced safety measures make it a standout choice for homeowners looking to enhance their living spaces with a dependable gas fireplace. Whether for cozy family gatherings or quiet evenings at home, the C-40 offers both aesthetic appeal and functional excellence, ensuring it remains a popular choice in contemporary home design.