A.Design, Installation & Location Considerations

1. Appliance Location

Consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation.

If you are not using an existing chimney, place the appliance in a location to maintain a clear passage for the installation of any listed and approved pellet venting system. This appli- ance may be vented vertically or horizontally.

Maintain specified vent clearance to comubstible require- ments listed by the pellet manufactures venting instructions and all clearance to combustivles listed in this manual.

Check with your local building code agency before you begin your installation. Be sure local building codes do not super- sede UL specifications and always obtain a building permit so that insurance protection benefits cannot be unexpectedly cancelled. If any assistance is required during installation, please contact your local dealer.

We recommend that a qualified building inspector and your insurance company representative review your plans before and after installation.

2. Thermostat Location

The thermostat’s location will have some effect on the appliance’s operation. When the thermostat is located close to the appliance, it may require a slightly higher temperature setting to keep the rest of the house comfortable. If the thermostat location is in an adjacent room or on a different floor level, you will notice higher temperatures near the appliance.

CAUTION

Do NOT connect this unit to a chimney flue servicing another appliance.

Do NOT connect to any air distribution duct or system.

B. Fire Safety

Maintain the designated clearances to combustibles. Insu- lation must not touch the chimney. You must maintain the designated air space clearance around the chimney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE:

Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.

To provide reasonable fire safety, the following should be given serious consideration:

1.Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the heating appliance and close to the sleeping areas. Follow the smoke detector manufacturer’s placement and installation instructions, and be sure to maintain regularly.

2.A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers.

3.A practiced evacuation plan, consisting of at least 2 escape routes.

4.A plan to deal with a hopper fire as follows: In the event of a hopper fire:

a.Evacuate the house immediately.

b.Notify fire department.

WARNING

Fire Risk.

Do not operate appliance before reading and understanding operating instructions.

Failure to operate appliance properly may cause a house fire.

September 1, 2008

250-7251F

Page 5

Page 5
Image 5
Hearth and Home Technologies CASTINS-CWL Getting Started, Design, Installation & Location Considerations, Fire Safety

CASTINS-CWL, CASTINS-CSB, 810-03201 (PMH), 810-02901 (MBK) specifications

Hearth and Home Technologies has made a significant mark in the hearth and home industry with a variety of innovative products, including models like the 810-02901 (MBK), 810-03201 (PMH), CASTINS-CSB, and CASTINS-CWL. These models reflect state-of-the-art design and engineering, ensuring comfort and efficiency in residential heating solutions.

The 810-02901 (MBK) model is designed primarily for modular design, allowing for easy installation and integration into various home architectures. This model features advanced combustion technology that maximizes fuel efficiency while minimizing emissions. It is equipped with an innovative air control system that provides users with precise control over flame height and heat output, enhancing the overall user experience. With features such as a large viewing area, the MBK model provides an attractive look while ensuring optimum safety.

The 810-03201 (PMH) model offers versatile heating options and an elegant design that fits seamlessly into modern interiors. This model is notable for its user-friendly interface, which enables users to control settings with ease. It also has a remarkable heat distribution system, allowing warmth to spread evenly throughout the space, reducing cold spots and enhancing comfort. Additionally, the PMH model is built with durable materials that withstand the test of time, making it a long-lasting investment for homeowners.

The CASTINS-CSB and CASTINS-CWL models represent the pinnacle of contemporary fireplace design with their cast iron construction, enhancing durability and offering superior heat retention. Both models feature intricate designs that not only elevate the aesthetic of any room but also provide effective heating solutions. With the CASTINS series, Hearth and Home Technologies emphasizes the importance of safety with features such as heat shields and advanced flue systems that ensure proper ventilation.

In summary, Hearth and Home Technologies' 810-02901 (MBK), 810-03201 (PMH), CASTINS-CSB, and CASTINS-CWL models are characterized by their innovative technology, elegant design, and efficient heating capabilities. These models cater to a variety of homeowner needs, providing comfort, efficiency, and safety while enhancing interior aesthetics. Whether you’re looking for a robust heating solution or an elegant focal point in your home, Hearth and Home Technologies offers durable and stylish options that stand out in any environment.