Hearth and Home Technologies ESCAPE-42DV owner manual Troubleshooting, Intellifire Ignition System

Models: ESCAPE-42DV

1 57
Download 57 pages 27.42 Kb
Page 44
Image 44

14 Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.

A. Intellifire Ignition System

Sympton

Possible Cause

Corrective Action

 

 

 

1. The ignitor/module

a. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor

makes noise, but no

 

are connected to correct terminals on module and pilot assembly.

spark.

 

Reversed wires at the module may cause system to make sparking

 

 

noise, but spark may not be present at pilot hood.

 

 

 

 

b. Loose connections or electrical

Verify no loose connections or electrical shorts in wiring from mod-

 

shorts in the wiring.

ule to pilot assembly. Rod closest to pilot hood should be ignitor.

 

 

Verify connections underneath pilot assembly are tight; also verify

 

 

connections are not grounding out to metal chassis, pilot burner,

 

 

pilot enclosure, mesh screen if present, or any other metal object.

 

 

 

 

c. Ignitor gap is too large.

Verify gap of igniter to pilot hood. The gap should be approximately

 

 

.17 inch or 1/8 inch.

 

 

 

 

d. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF Rocker switch or wall

 

 

switch in ON position. Hold ground wire about 3/16 inch away from

 

 

“I” terminal on module. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

2. Pilot won’t light,

a. Transformer installed correctly.

Verify that transformer is installed and plugged into module. Check

there is no noise or

 

voltage of transformer under load at spade connection on module

spark.

 

with ON/OFF switch in ON position. Acceptable readings of a good

 

 

transformer are between 3.2 and 2.8 volts AC.

 

 

 

 

b. A shorted or loose connection in wir-

Remove and reinstall the wiring harness that plugs into module.

 

ing configuration or wiring harness.

Verify there is a tight fit. Verify pilot assembly wiring to module.

 

 

Remove and verify continuity of each wire in wiring harness.

 

 

 

 

c. Improper wall switch wiring.

Verify that 110/VAC power is “ON” to junction box.

 

 

 

 

d. Module not grounded.

Verify black ground wire from module wire harness is grounded to

 

 

metal chassis of appliance.

 

 

 

 

e. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF Rocker switch or wall

 

 

switch in ON position. Hold ground wire about 3/16 inch away from

 

 

“I” terminal on module. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

3. Pilot lights but con-

a. A shorted or loose connection in

Verify all connections to wiring diagram in manual. Verify connec-

tinues to spark, and

sensor rod.

tions underneath pilot assembly are tight. Verify connections are

main burner will not ig-

 

not grounding out to metal chassis, pilot burner, pilot enclosure or

nite. (If the pilot contin-

 

screen if present, or any other metal object.

ues to spark after the

 

 

b. Poor flame rectification or contami-

Verify that flame is engulfing sensor rod. If the pilot assembly does

pilot flame has been lit,

flame rectification has

nated sensor rod.

not have a ground strap, consider installing one to increase flame

 

rectification. Verify correct pilot orifice is installed and inlet gas

not occurred.)

 

 

specifications. Flame carries rectification current, not the gas. If

 

 

 

 

flame lifts from pilot hood, the circuit is broken. A wrong orifice or

 

 

too high an inlet pressure can cause pilot flame to lift. The sensor

 

 

rod may be contaminated. Clean sensor rod with emery cloth.

 

 

 

44

Heat & Glo • Escape-42DV2052-900 Rev. R • 10/08

Page 44
Image 44
Hearth and Home Technologies ESCAPE-42DV owner manual Troubleshooting, Intellifire Ignition System

ESCAPE-42DV specifications

Hearth and Home Technologies has established itself as a leader in the hearth industry, bringing innovation and style to homes across North America. One of their standout offerings is the ESCAPE-42DV, a versatile and efficient direct vent gas fireplace that combines modern design with cutting-edge technology.

The ESCAPE-42DV features a sleek, contemporary look that seamlessly integrates into various home aesthetics. With a viewing area of 42 inches, it provides a wide and inviting flame display that enhances the ambiance of any living space. Its generous size makes it an ideal centerpiece for larger rooms, allowing for a captivating focal point in homes with open floor plans.

One of the notable characteristics of the ESCAPE-42DV is its direct vent technology, which allows for efficient operation without the need for a traditional chimney. This system ensures that combustion gases are expelled outside while bringing in fresh air for combustion, creating a cleaner and more energy-efficient environment. Homeowners can enjoy the warmth and comfort of real flames without the hassle of maintaining a complex venting system.

Efficiency is key in today's eco-conscious world, and the ESCAPE-42DV exceeds expectations with its impressive energy ratings. It operates at a high efficiency level, providing excellent heating capability while minimizing gas consumption. This not only reduces utility bills but also makes it an environmentally friendly choice, appealing to those who prioritize sustainability.

Hearth and Home Technologies have also incorporated advanced features into the ESCAPE-42DV, including a variety of heat and flame control options. The unit comes equipped with a programmable remote control, allowing users to adjust the flame height and heat output with ease. This personalization ensures comfort whether homeowners are looking for a cozy ambiance or substantial warmth during colder months.

The fireplace can be styled according to individual preferences, thanks to customizable options such as various media choices, including beautiful ceramic logs and glowing embers. The ability to personalize the appearance of the ESCAPE-42DV enhances its appeal, making it a functional yet stylish addition to any home.

With its combination of design elegance, innovative technology, and operational efficiency, the Hearth and Home Technologies ESCAPE-42DV direct vent gas fireplace is an exceptional choice for homeowners seeking to elevate their living spaces. It stands as a testament to the brand's commitment to quality and innovation in the hearth industry, delivering warmth and beauty to modern homes.