Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07 7
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
Report damaged parts to dealer.
WARNING
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
Installation and use of any damaged appliance or
vent system component.
• Modi cation of the appliance or vent system.
Installation other than as instructed by Hearth & Home
Technologies.
Improper positioning of the gas logs or the glass
door.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Any such action may cause a re hazard.
WARNING
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Reciprocating saw Framing material
Pliers Hi temp caulking material
Hammer Gloves
Phillips screwdriver Framing square
Flat blade screwdriver Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level Manometer
Voltmeter Tape measure
Non-corrosive leak check solution
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
One 1/4 in. female connection (for optional fan)
D. Inspect the Appliance and Components
The following B-vent components are needed for installa-
tion. See Figure 2.2.
• Appliance
• Pipe components
• Firestops
Attic insulation shield
• Elbows
• Strapping
• Roof ashing or chase top
• Termination cap
• Storm Collar
Carefully remove the appliance and components from the
packaging.
The vent system components and trim doors are shipped
in separate packages.
The gas logs may be packaged separately and must be
eld installed.
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
• Read all of the instructions before starting the
installation. Follow these instructions carefully
during the installation to ensure maximum safety and
bene t.
Vertical
Termination
Cap
Roof
Flashing
Ceiling
Firestop
B-Vent Pipe
Sections
Storm
Collar
Figure 2.2 Typical Vertical Installation