Heatilator • RBV4236/RBV4842 • 4048-210 Rev K • 02/07 5

A. Design and Installation Considerations

Heatilator B-vent gas appliances are designed to operate
with all exhaust gases expelled to the outside of the building,
and combustion air pulled from the room.
Check building codes prior to installation.
Installation MUST comply with local, regional,
state and national codes and regulations.
• Consult insurance carrier, local building, fire
of cials or authorities having jurisdiction about
restrictions, installation inspection, and permits.
CAUTION
When planning an appliance installation, it’s necessary to
determine the following information before installing:
Where the appliance is to be installed. See Section 3.
The vent system con guration to be used. See Sections
4 and 5.
Gas supply piping. See Section 9.
• Electrical wiring. See Section 10.
• Framing and finishing details. See Sections 3, 6
and 11.
Whether optional accessories—devices such as a fan, wall
switch, or remote control—are desired. See Section 10.
Keep appliance dry.
• Mold or rust may cause
odors.
Water may damage controls.
WARNING
2