C. 240VAC Hardwire Installation | D. Wall Switch Wiring (12VDC) | |
• | Turn off circuit breaker. | *Do not connect wires to 120/240VAC* (hardwired heat- |
• | Access knockout. | ers only) |
|
•Remove the access cover plate.
•Disconnect the power cord from the terminal block.
•Remove the knockout and install the cable clamp (not provided) into the hole.
•Feed 8 in. of service wire through the cable clamp and secure.
•Connect the black wire from the service to the L1 terminal.
•Connect the red wire from the service to the L2 terminal.
•Connect the white wire from the service to the N terminal.
•Connect the green (ground) from the service to the GND terminal.
•Optional wall switch wiring is to be done at this time.
•Replace access cover plate.
•Turn off circuit breaker.
•Access knockout.
•Remove the access cover plate.
•Feed 16 in. of service wire through the cable clamp and secure.
•Low voltage wire can be used for the wall switch connection.
•Locate the loop of blue wire on the accessory connector.
•Cut the loop and connect one side to one of the wall switch wires and the other side to the other wire for the switch.
•Replace the access cover plate.
•Run the wall switch wire to the wall box and connect to a wall switch
LAMP | LAMP | FLAME M0TOR |
|
|
|
| 120 VAC | R2 | B | A | |
|
| ||||
| LAMPS |
| SPEED |
|
|
|
|
|
|
| |
|
|
| CONTROL |
|
|
|
|
|
|
| |
| DIMMER |
|
|
|
|
|
| OPTIONAL |
| THERMOSTAT | |
|
| REMOTE OR | REMOTE HEAT | D1 | RELAY |
|
|
| |||
|
| WALL ON/OFF | CONTROL | DIODE |
|
| B | SWITCH |
|
|
|
|
|
|
|
| |
| - | + |
|
| HEAT SWITCH |
|
|
|
| ||
| A | 12VDC |
|
|
|
|
| SUPPLY | BLOWER |
|
|
|
|
|
|
|
| PE | POWER | WHITE |
|
|
| BLOWER |
|
|
| BLOWER |
| |||
|
|
|
| 120 VAC |
|
| |
| N |
|
|
|
|
| |
|
| BLACK |
|
| HIGH LIMIT | HEATER 1 | |
| 120 V | HIGH LIMIT | HEATER 1 | ||||
| BLACK | ||||||
|
| ||||||
| L1 |
|
|
|
| 240 VAC |
|
120 V | 240 V |
| RED |
|
| HEATER 2 | |
|
|
| RED |
| |||
| L2 |
|
|
|
|
|
|
TERMINAL STRIP | 3 PIN WIRING | POWER NEUTRAL MUST NOT |
HARNESS | CONNECT TO VIRTUAL NEUTRAL | |
120 VAC PLUG OR 120/240 |
| OF HEATERS OR BLOWER IN |
HARD WIRED |
| |
| 240VAC VERSION | |
|
|
120VAC - 240VAC 60 HZ
Figure 4.1 120V/240V Wiring Diagram
10 | Heatilator • SILHOUETTE Series Electric Fireplace • |