3
Figure 4. Millivolt with Rocker Switch and Receiver
Figure 5. Millivolt with 3 Wire
If your fireplace is wired like Figure 3 find the leads on back of the switch marked “For use with remote or wall switch only” and
take the leads and plug them into wire lead on remote receiver box (see Figure 4).
3-WIRE ASSEMBLY
PIEZO
RED
WHITE
PILOT
THERMOCOUPLE
VALVE
If your fireplace is wired like Figure 5 remove 3 wires from the valve by unplugging the spade from the valve. Install the jumper
wire on the terminal on the valve as shown in Figure 6. Then install one of the leads from the receiver onto the valve and the
other wire onto the lead from the jumper wire.
B. Wiring Millivolt Valve with 3-Wire Assembly
FEMALE MALE
MALE FEMALE
RED
BROWN
VALVE
123
REMOTE
RECEIVER
BOX
ON/OFF
REMOTE SWITCH
FOR USE
WITH REMOTE
OR WALL
SWITCH ONLY