Heat & Glo LifeStyle 6000GL-IPI-S, 6000GL-IPILP-R, 6000GL-IPILP-S D. Electrical Service and Repair

Models: 6000GL-IPILP-R 6000GL-IPI-R 6000GL-IPILP-S 6000GL-IPI-S

1 67
Download 67 pages 5.54 Kb
Page 48
Image 48
D. Electrical Service and Repair

PLUG-IN

3V TRANSFORMER

ON/OFF

WALL SWITCH

IGNITION MODULE (3V)

VALVE

LOW VOLTAGE

 

SEE NOTE 1

NEUTRAL

GROUND REMOTE

 

CONTROL HOT

BLACK WIRE CAN BE

PLUGGED INTO ANY

OF #1 - #5 LOCATIONS

ON THE HOT SIDE

WHITE WIRE CAN BE

PLUGGED INTO ANY

OF#1 - #5 LOCATIONS

ON THE NEUTRAL SIDE

TRANSFORMER

3 VAC

PLUG-IN

IGNITION MODULE 3 VAC

ORG

WHT

 

GROUND TO

 

FIREPLACE

 

CHASSIS*

BLK

ORG

 

RED

BRN

BRN

VALVE

REMOTE

JUMPER WIRE

INTERMITTENT

PILOT IGNITOR

Note: Appliance will not operate unless properly grounded.

GRN

THERMOSTAT

WIRE

ASSEMBLY

Figure 12.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation.

48

Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S2102-900 Rev. R • 6/09

Page 48
Image 48
Heat & Glo LifeStyle 6000GL-IPI-S, 6000GL-IPILP-R, 6000GL-IPILP-S, 6000GL-IPI-R owner manual D. Electrical Service and Repair