Top Vent - Vertical Termination

Top Vent - Vertical Termination

No Elbow

V1 = 40 ft. Max. (12.4 m)

V1 = 3 ft. Min. (914 mm)

Note: If installing a vertical vent/ termination off the top of the ap- pliance, the flue restrictor should be used.

V1

Figure 7.6

Flue Restrictor Instructions

1.Remove exhaust shield using a 1/4 inch nut driver by removing the four screws securing it in place (see Figure 7.7).

EXHAUST

SHIELD

FLUE

RESTRICTOR

Figure 7.7

2.Break the flue restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.8).

BREAK

HERE

Figure 7.8 Flue Restrictor

26

Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S2102-900 Rev. R • 6/09