Heat & Glo LifeStyle 6000TR-OAK-IPI owner manual Wiring the Fireplace

Models: 6000TR-OAK-IPI

1 35
Download 35 pages 14.85 Kb
Page 30
Image 30
Step 9. Wiring the Fireplace

3/16” PIGGYBACK CONNECTOR

 

 

BLACK S2

REMOTE SWITCH

 

 

 

PIGTAIL

 

 

 

ON

 

 

 

 

OFF

 

 

WHITE T2

ON/OFF

 

 

SWITCH

 

GAS VALUE

RED T1

 

 

 

 

 

 

 

THERMOPILE

 

 

THERMOCOUPLE

 

 

 

OPTIONAL WALL SWITCH,

 

 

BLACK S1

 

Figure 35. Standing Pilot Ignition Wiring Diagram

 

THERMOSTAT OR REMOTE

 

 

 

 

 

Step 9. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENTAL FIREPLACE OPERATION.

For Standing Pilot Ignition Wiring

Appliance Requirements

This appliance DOES NOT require 110-120 VAC to operate.

!WARNING: DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL VALVE OR THE AP- PLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED.

Optional Accessories

Optional fan and remote control kits require that 110-120 VAC be wired to the factory installed junction box before the fireplace is permanently installed.

Wall Switch

Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/ OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC ! TO THE WALL SWITCH OR THE CONTROL

VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPERAND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

 

 

VARIABLE SPEED CONTROL

 

 

 

 

NOTE: IF ANY OF THE ORIGINAL WIRE

 

 

 

AS SUPPLIED WITH THE APPLIANCE

 

BLK

BLK

MUST BE REPLACED, IT MUST BE

 

JUNCTION BOX

REPLACED WITH TYPE 105OC RATED WIRE.

 

 

 

BLK

 

BLK

BLOWER RECEPTACLE

 

 

 

BLK

 

BLK

 

 

 

 

 

BLK

WHT WHT

BLK

GROUND

TEMPERATURE

SENSOR SWITCH

BLOWER

GRN

BLKWHT

110-120 VAC

BLOWER

SENSOR

SWITCH

“FAN”

RECEPTACLE SPEED Manual background CONTROL

Figure 36. Fan Wiring Diagram

30

Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI383-901 Rev. K • 5/06

Page 30
Image 30
Heat & Glo LifeStyle 6000TR-OAK-IPI owner manual Wiring the Fireplace