Heat & Glo LifeStyle EM-485T - 42 E. Install Outside Air Kit, F. Junction Box Installation, Hood

Models: EM-485T - 42 EM-415 - 36

1 53
Download 53 pages 31.25 Kb
Page 23
Image 23
E. Install Outside Air Kit

E. Install Outside Air Kit

Keep duct runs short and straight to minimize restriction. A small dip is acceptable for a cold air trap.

The outside air kit must be installed on the left hand side of the fireplace.

Locate the air inlet in a clear area, preferably into prevailing wind during the heating season. Refer to Figure 5.2.

Install as shown in Figures 7.3, 7.4 and 7.5.

The air duct may be run vertically.

The outside air inlet must be at least 3 ft (.91 m) below the top of the uppermost chimney section.

Caution! Risk of Fire or Asphyxiation! Do not draw outside combustion air from wall, floor or ceiling cavity, or enclosed spaces such as an attic or garage.

Do not place outside air inlet close to exhaust vents or chimneys. Fumes or odor could be drawn into the room through the fireplace.

Locate outside air inlet to prevent blockage from leaves, snow/ice, or other debris. Blockages could cause combus- tion air starvation.

Flexible Duct (not supplied)

Outside Air

 

 

Hood

2 Wire Ties

Inlet Ring

Hearth & Home Technologies Inc recommends using UL181 Class 0 or Class I rigid or flexible ducting.

Secure flex duct with metal tape, screws or wire ties.

Figure 7.5 Outside Air Installation

F. Junction Box Installation

Notice: Junction box should be installed during initial setup to avoid major reconstruction.

Your appliance is supplied with a junction box kit. We recommend the junction box be installed and wired at this time to avoid reconstruction.

The junction box kit is to be installed on the right side of the appliance; remove and discard the metal knockout.

Attach the junction box bracket to the junction box as shown in Figures 7.6 - 7.10.

Bring the electrical wires to the inside of the junction box and secure in place with the Romex connector.

Install the duplex receptacle in the junction box and attach the cover plate.

Prior to attaching the junction box to the appliance, the heat shield supplied with your appliance must be installed. Insert the top flange of the heat shield through the electrical knockout hole from the inside (Figure 7.9).

Attach the junction box bracket to the side of the appliance. See Figure 7.10. Secure with the screws provided in the fastener package.

Heat & Glo • EM-415, EM-485 • 33056 • Rev AF 7/12

23

Page 23
Image 23
Heat & Glo LifeStyle EM-485T - 42 E. Install Outside Air Kit, F. Junction Box Installation, Flexible Duct not supplied