Heat & Glo LifeStyle EM-485T - 42 H. Glass Doors, K. Vented Gas Log Sets & Gas Log Lighters

Models: EM-485T - 42 EM-415 - 36

1 53
Download 53 pages 31.25 Kb
Page 9
Image 9
H. Glass Doors

H. Glass Doors

Glass doors are optional.

Refer to Figure 2.2 for how to properly use them.

WARNING! Risk of Fire! Install ONLY doors ap- proved by Hearth & Home Technologies, Inc.

WARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and fl ame may be drawn out of the fi replace opening.

FULLY OPEN

PARTLY OPEN

CORRECT

INCORRECT

FULLY CLOSED

PARTLY CLOSED

CORRECT

INCORRECT

Figure 2.2 Operating Positions of Bi-fold Doors

K. Vented Gas Log Sets & Gas Log Lighters

Optional.

Vented gas logs or gas log lighters can be installed in this fi replace. Follow the instructions provided with the accessory for operation.

WARNING! Risk of Fire or Asphyxiation!

DO NOT install unvented gas logs.

Damper must be locked open.

Gas fl ame may generate fumes.

L. Optional Components

Other options may be available

Consult your dealer/distributor

WARNING! Risk of Fire! DO NOT install and or use any component not approved by Hearth & Home Tech- nologies Inc.

M. Clear Space

Do not place combustible objects within 48 in. (1219 mm) of the front of fi replace. See Figure 2.3.

WARNING! DO NOT place combustible objects in front of the fi replace. High temperatures may ignite clothing, furniture or draperies.

Mantel - avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects.

I. Outside Air (optional)

The outside air kit supplies some fresh combustion air for your fi replace. It may help reduce the effects of negative air pressure. (See Section 5.D.)

Refer to Figure 2.1 for location of control

Close the inlet to prevent cold drafts when the fi replace is not being used.

CAUTION! Risk of Burns! The outside air control handle is HOT when fi replace is in operation. Adjust BEFORE lighting fi re.

J. Fan Kit (optional)

Refer to instructions included with fan kit.

48 in. (1219 mm)

Clear Space

Front of Fireplace

Figure 2.3 Clear Space

12 in. (305 mm) Clear Space K. Vented Gas Log Sets & Gas Log Lighters

Sides of Fireplace

(from the FP

opening)

Heat & Glo • EM-415, EM-485 • 33056 • Rev AF 7/12

9