E. Locating Fireplace & Chimney

Location of the fireplace and chimney will affect perfor- mance.

Install within the warm airspace enclosed by the building envelope. This helps to produce more draft, especially during lighting and die-down of the fire.

Penetrate the highest part of the roof. This minimizes the effects of wind loading.

Locate termination cap away from trees, adjacent structures, uneven roof lines and other obstructions.

Minimize the use of chimney offsets.

Consider the fireplace location relative to floor and ceiling and attic joists.

Take into consideration the termination requirements in Section 8 and Section 9.

NoTICE: Locating the fireplace in a basement or in a location of considerable air movement can cause intermittent smoke spillage from fireplace. Do not locate fireplace near

frequently open doors

central heat outlets or returns

Location NOT recommended:

Not the highest point of the roof

Wind loading possible

Windward

 

Recommended Location:

Recommended Location:

Above peak

• Above peak

Inside heated space

Marginal Location:

Marginal Location:

• Wind loading possible

• Below peak

 

Recommended:

Insulated exterior chase in cooler climates

Location NOT recommended:

Too close to tree

Below adjacent structure

Lower roof line

Avoid outside wall

Leeward

Multi-level Roofs

Figure 5.2 Recommended Chimney Locations