Heat & Glo LifeStyle HST-42D owner manual A. Chimney Requirements

Models: HST-42D

1 49
Download 49 pages 513 b
Page 25
Image 25
A. Chimney Requirements

A. Chimney Requirements

Measure vertical distances from the base of the fireplace as shown in Figure 8.2.

 

 

ft

merst

• Minimum overall straight height

14

4.27

• Minimum height with offst/return

165.

5.03

Maximum height

90

2743.

• Maximumchimneylengthbewtweenanoffset

20

6.10

and return

 

 

Maximumdistancebetweenchimneystabilizers

35

1067.

• Double offset/return minimum height

20

6.10

• Maximumunsupportedchimneylengthbetween

6

1.83

the offset and return

 

 

• Maximumunsupportedchimneyheightabovethe

35

1067.

fireplace

 

 

Maximumunsupportedchimneyaboveroof 6 1.83

Warning! Risk of Fire! You must maintain 2 in. (51

mm)air space clearance to insulation and other combus- tible materials around the chimney system. Failure to do so may cause overheating and fire.

Table 8.1

Determine the chimney components needed to complete your particular installation:

Measure the total vertical height of the fireplace installation from the base of the fireplace assembly to the approximate location of the bottom of the termination cap.

Subtract the effective height of the fireplace assembly (see Figure 8.2) from the total vertical height to determine the overall height of the chimney installation.

Create a schematic for your application similar to Figure 8.2 showing components required (referring to Table 8.1). Figure 8.1 identifies those components and where used.

Install a ceiling firestop whenever the chimney penetrates a floor/ceiling.

Notice: A maximum of two pairs of offsets and returns may be used.

Caution! Risk of Fire and/or Asphyxiation! DO NOT connect this fireplace to a chimney flue servicing another appliance. Do NOT connect to any air distribu- tion duct or system. These actions could cause over- heating/fire in the chimney flue, or release of exhaust fumes into the living areas.

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

Chimney Stabilizer

 

 

 

SL3

4-3/4

121

 

 

 

 

Ceiling Firestops

 

 

 

FS338

0

0

 

FS339

0

0

 

 

 

 

 

FS340

0

0

Offsets/Returns

 

 

 

SL315

13-3/8

340

 

SL330

15-1/2

394

Roof Flashing

 

 

 

RF370

0

0

 

RF371

0

0

 

 

 

 

Chimney Sections*

 

 

 

SL306

4-3/4

121

 

SL312

10-3/4

273

 

 

 

 

 

SL318

16-3/4

425

 

SL324

22-3/4

578

 

SL336

34-3/4

883

 

 

 

 

 

SL348

46-3/4

1187

* Dimensions reflect effective height.

 

 

20 ft (6.10 m) max. pipe between an offset & return

Ceiling firestop

47-1/4 in.

(1200 mm)

Effective

Height

6 ft (1.83 m) max.

Table 8.1Manual backgroundunsupported chimney

above roof

35 ft (10.67 m) max. straight unsupported chimney height

16 ft (4.88 m) min. height (single offset-return) 20 ft. (6.10 m) min. height (double offset-return)

90 ft (27.4 m) max. height

Figure 8.2 Chimney Requirements

Heat & Glo • HST-42D • 27177 • Rev AG • 7/12

25

Page 25
Image 25
Heat & Glo LifeStyle HST-42D owner manual A. Chimney Requirements