Note: The following requirements reference various Massachusetts and national codes not contained in this document.

H. Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detec- tor with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu- eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2) (a)1 through 4:

The equipment listed in Chapter 10 entitled “Equip- ment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure sep- arate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro- vide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment in- stallation instructions; and

The “special venting systems” shall be Product Ap- proved by the Board, and the instructions for that sys- tem shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Common- wealth of Massachusetts requirements.

Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD2189-900 Rev. i • 5/12

5

Page 5
Image 5
Heat & Glo LifeStyle PALOMA-BZ-MOD owner manual Requirements for the Commonwealth of Massachusetts

PALOMA-BZ-MOD specifications

The Heat & Glo LifeStyle PALOMA-BZ-MOD is an innovative and stylish gas fireplace designed to elevate the ambiance of any living space. This modern fireplace combines functionality, aesthetics, and advanced technology, making it an ideal choice for homeowners seeking both warmth and sophistication.

One of the standout features of the PALOMA-BZ-MOD is its contemporary design. With its clean lines and minimalist profile, this fireplace seamlessly integrates into various interior styles—from ultra-modern to classic decor. The wide viewing area provided by the expansive glass front ensures that the mesmerizing flames are the focal point of any room, creating an inviting and cozy atmosphere.

The PALOMA-BZ-MOD incorporates advanced heating technologies that enhance efficiency and performance. Its powerful heating capacity can warm spaces effectively, allowing for comfortable living even in colder climates. The unit is designed to operate quietly, ensuring that the crackling flames are the only sound you hear. This makes it perfect for homes where relaxation and tranquility are priorities.

Another noteworthy aspect of the PALOMA-BZ-MOD is its customizable features. Homeowners can choose from a variety of decorative media options, including ceramic logs, glass beads, or pebbles, allowing for personalization that complements individual style preferences. The flame presentation is adjustable, giving users control over the height and intensity of the flames, thus enhancing both aesthetics and functionality.

The fireplace is equipped with innovative technologies for ease of use. The flexible installation options mean it can be placed in a variety of locations, whether it's a central feature in a living room or an elegant addition to a dining area. Additionally, a user-friendly remote control allows for convenient operation, enabling users to turn the fireplace on or off and adjust settings from across the room.

Safety is a priority with the PALOMA-BZ-MOD. It features an advanced safety shut-off system, ensuring peace of mind for homeowners. The continuous pilot light and electronic ignition system enhance reliability, providing instant warmth when needed.

In summary, the Heat & Glo LifeStyle PALOMA-BZ-MOD exemplifies a harmonious blend of modern design and advanced technology. With its captivating flames, customizable features, and efficient heating performance, it serves as both a functional heating solution and a stunning piece of decor, making it a popular choice for any contemporary home.