2 Getting Started

A. Design and Installation Considerations

Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.

Heat & Glo gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fireplaces that have been installed in accordance with the National, Provincial, State and local building codes.

Prior to installing the gas insert:

Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certi- fied professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.

Replace component parts of the chimney and fireplace as specified by the professionals.

Ensure all joints are properly engaged and the chimney is properly secured.

When planning an appliance installation, it’s necessary to determine the following information before installing:

Minimum fireplace size. See Section 3.A.

Gas supply piping.

Electrical wiring.

Finishing details.

Existing mantel, mantel legs and wall projection loca- tions. See Section 3.C.

Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.

B. Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Pliers

Hi temp caulking material

Hammer

Flat blade screwdriver

Voltmeter

Framing square

Gloves

Variable speed drill

1/4 Hex drive

Safety glasses

Manometer

Phillips screwdriver

Tape measure

Non-corrosive leak check solution

1/2 - 3/4 inch length, #6 or #8 Self-drilling screws

C. Inspect Appliance and Components

WARNING

Inspect appliance and components for damage. Damaged parts may impair safe operation.

• Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components. Report damaged parts to dealer.

Carefully remove the appliance and components from the packaging.

The vent system components, surrounds and fronts are shipped in separate packages.

The fiber logs may be packaged separately and must be field installed.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the insta- llation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

WARNING

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modification of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

WARNING

Keep appliance dry.

• Mold or rust may cause odors.

• Water may damage controls.

Heat & Glo • Supreme-XTS, Grand-XTS349-901 Rev. i • 12/09

5

 

Page 5
Image 5
Heat & Glo LifeStyle GRAND-XTS Getting Started, Design and Installation Considerations, Tools and Supplies Needed