Installation, Operation and Maintenace Manual
GeoLogix HTS Series Split System
Two Stage, 2-5Tons
Installation
Table of Contents
Electrical - Low Voltage Wiring
Low Water Temperature Cutout Selection
Model Nomenclature : for Indoor Split Series
Safety
Safety
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Inspection
General Information
Pre-Installation
Prepare units for installation as follows
Indoor Coil Selection - HTS GeoLogix
Equipment Selection
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
General
Equipment Selection
Air Handler Selection Example
Figure 1: Selecting Air Handler
Indoor Compressor Section Location
Installation
Air Handler and Coil Installation
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
GROUND-LOOPHEAT PUMP APPLICATIONS
Installation
Pre-Installation
Piping Installation
Antifreeze
Ground-LoopHeat Pump Applications
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Flushing the Earth Loop
15F -9.4C
Ground-LoopHeat Pump Applications
Type
10F -12.2C
Water Quality Standards
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Open Loop - Ground Water Systems
“Indoor” Compressor Section Only
Optional Modulating Motorized Valve - For Open
Ground-WaterHeat Pump Applications
Water Coil Low Temperature Limit Setting
Sizes024 -
Corrosion Prevention
Water Quality Standards
Scaling Potential - Primary Measurement
Iron Fouling
Refrigeration Installation
Line Set Installation
Installing the Lineset at the Compressor Section
Add-OnHeat Pump Applications
Refrigeration Installation
Installing the Indoor Coil and Lineset
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Refrigeration Installation
Evacuation Of The Lineset And Coil
Refrigeration Installation
NOTICE
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Determining Superheat
Refrigeration Installation
FINAL EVALUATION
Checking Superheat and Subcooling
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Hot Water Generator
CONNECTIONS
ANTI-SCALD
Hot Water Generator
VALVE PIPING
Hot Water Generator
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Table 6: HWG Water Piping Sizes and Length
HWG Wiring - Indoor Compressor Section
Electrical - Line Voltage
General Line Voltage Wiring
Power Connection
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Electrical - Low Voltage
Low Water Temperature Cutout Selection
Accessory Connections
Thermostat Installation
Electrical - Thermostat Wiring
ECM fan
DXM2 Controls
Conventional
Unit
Figure 26a: DXM2 Layout and Connections
P11P10
P9 CC
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Notes
Unit Commissioning And Operating Conditions
Operating Limits
Commissioning Conditions
SERVICE MODE
INSTALLER SETTINGS THERMOSTAT CONFIG
SYSTEM CONFIG ACCESSORY CONFIG INPUT DEALER INFO
HUMIDITY CONFIG TEMPERATURE ALGORITHM
FAULT HISTORY CLEAR FAULT HISTORY
Unit Start-UpProcedure
SERVICE MODE
CONTROL DIAGNOSTICS DIPSWITCH CONFIG
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Unit Operating Conditions
Entering
Based on 15% methanol antifreeze solution
Based on 15% methanol antifreeze solution
Unit Operating Conditions
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Preventive Maintenance
Water Coil Maintenance
Water Coil Maintenance
Sensor Inputs
Basic Troubleshooting Information
General Troubleshooting
DXM2 Field Inputs
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
General
System Configuration
Service Mode
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
DXM2 Process Flow Chart
DXM2 Functional Troubleshooting Flow Chart
Start
Possible Cause
Functional Troubleshooting
Fault
Solution
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
Functional Troubleshooting
Fault
Solution
Possible Cause
Performance Troubleshooting
Symptom
Solution
7\SH
Troubleshooting Form
HEAT CONTROLLER, INC. WATER-SOURCEHEAT PUMPS
+$7,1*&<&/$1$/<6,6
Notes
DARD
97B0016N18
The Quality Leader in Conditioning Air