TROUBLE SHOOTING

 

12.

TROUBLE SHOOTING

 

 

 

 

 

 

 

 

 

 

 

 

Problem

Cause

Solution

 

 

 

 

 

 

 

Power failure or plug is not

Restore the power supply or

The unit doesn’t run

correctly inserted in the socket

reset LCDI

 

 

Circuit breaker or line fuse has

Call your Electrician

 

 

been tripped

 

 

 

 

Power supply voltage is too low

Call your Electrician

The unit has only fan,

The room temperature is not at

Check your room temperature

no cooling even

working range

 

 

though it is in the

The set temperature is too high

Re-set the temperature to a lower

cooling mode

 

temperature

 

 

The filter is dirty and obstructed

Clean the filer

 

 

Evaporator air is blocked

Remove the blockage

The unit seems to do

The air intake and outlet ducts of

Check both of the ducts

little cooling or does

the condenser side are obstructed

 

 

not cool quickly

There is direct sunshine into room

Close the curtains or blinds

 

 

The unit is set on dehumidifying

Set at cooling mode

 

 

mode

 

 

 

 

Set at low fan speed

Re-set the fan speed at high

 

 

 

speed

 

 

Windows or doors are open.

Close all of the windows and

The unit has worked

 

doors when the unit is working

for a long time, but the

Too many people in the room

Turn on other cooling unit

room is not cold

Something else in the room

Turn off these products

enough

produces heat

 

 

 

 

The room is not well insulated,

 

 

 

 

such as sunrooms, garages,

 

 

 

 

attics, etc.

 

 

 

 

The unit is not sitting evenly

Place the unit on an even surface

Too noisy

The floor underneath the unit is

Change the position

 

 

uneven

 

 

The unit stops cooling

The environment is too wet and

Empty the water inside the unit.

suddenly, only the fan

the condensate water in the unit is

Connect a pipe to the upper drain

works and the

full

port (refer to drawing in PARTS

Water-Full indicator

 

Of Unit) at the back of the unit

 

 

 

then restart the unit. Wait for

 

display on the

 

approximately 1 hour to let

control pane is on

 

condensor side fan blow out the

 

 

 

water

 

 