Disassembly
Refrigerationcycle
CAUTION: Discharge the refrigerant system using FreonTM Recovery System.If there is no valve to attach the recovery system, install one (such as a WATCO
16. CONDENSER
1. Remove the cabinet. (Refer to section 2)
2. Remove the brace and the shroud cover. (Refer to section 4)
3. Remove 2 screws which fasten the side cover.(See Fig. 31)
4. Remove the 5 or 6 screws which fasten the condenser.
5. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.
6. Remove the condenser.
7.
Figure 31
17.EVAPORATOR
1.Remove the cabinet. (Refer to section 2)
2.Remove the top cover and the brace. (Refer to section 4)
3.Discharge the refrigerant completely.
4.Remove the 3 screws which fasten the evaporator at the left side and the top side.
5.Move the evaporator sideward carefully and then unbraze the interconnecting tube at the evaporator connectors.
6.Remove the evaporator.
7.
18. CAPILLARY TUBE
1. Remove the cabinet. (Refer to section 2)
2. Remove the brace. (Refer to section 4)
3. After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube.
4. Remove the capillary tube.
5.
Figure 32