Heat Controller REG-183A, REG-243A manual Troubleshooting Guide, Unit runs but poor cooling

Models: REG-183A REG-243A

1 30
Download 30 pages 58.71 Kb
Page 23
Image 23
Troubleshooting Guide

Troubleshooting Guide

Unit runs but poor cooling.Manual backgroundTroubleshooting GuideManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

In general, possible trouble is classified in two kinds.

The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit runs but poor cooling.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (Heat exchanger)

Malfunction of fan

Clogged of air filter.

Obstruction at air outlet

Correct above trouble

Check clogging in refrigera- tion circuit.

Repair clogging in refrigera- tion circuit.

Check outdoor coil

(heat exchanger) & the fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air ; 44~50° F(7~10° C)

Check heat load increase.

Clean condenser.

Not on separate circuit.

Check inside gas pressure.

Adjusting of refrigerant charged.

Malfunction of compressor.

Replacement of compressor.

Service Manual 24

Page 23
Image 23
Heat Controller REG-183A, REG-243A manual Troubleshooting Guide, Unit runs but poor cooling