INSTALLATION

Estimated Installation Time: 30 minutes Items needed for installation (not included):

Phillips and flathead screwdrivers

Pliers

• Wire strippers/cutters

Safety glasses

• Silicone caulk

Ladder

• Black tape

WARNING: Turn power off at circuit breaker or fuse.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp screw joint.

Controls

Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

Wire the Light Control

These instructions show the sensor wired to floodlamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the switched “hot” wire. The lighting load (500Watts, 4.2 A max.incandescent only) is placed across the white and red wires.

Remove the existing light fixture, if present.

After screwing the sensor into the wall plate, connect the junction box wires to the light control wires by twisting together and securing with wire connectors.

2.RED CONTROL WIRE & BLACK FIXTURE WIRES

1.ALL WHITE WIRES

Junction Box

Bulb Holders

3. BLACK

 

 

CONTROL

 

 

WIRE & BLACK

 

 

Optional: Connect additional load

JUNCTION BOX

 

 

across the white and red wires. Total

WIRE

 

 

lighting load including bulb holders on

 

 

 

 

 

 

fixture must not exceed 500W (4.2A).

 

 

 

Mount the Light

Follow the instructions that came with your light fixture for mounting and adjusting the light fixture.

Keep regular PAR-38 bulbs at least 1" (25 mm) from the sensor. Halogen bulbs should be kept at least 2" (51 mm) from the sensor.

598-1115-04

Page 2
Image 2
Heath Zenith 2LBN3 manual Installation, Black