Heath Zenith 52-4477-8 Final Assembly, Testing and Adjustments, Optional Assembly

Models: 52-4477-8

1 16
Download 16 pages 19.15 Kb
Page 4
Image 4

Final Assembly

1.Push the wires into the junction box. Make sure the wires from the fixture go through the wire path, and no wires get pinched.

2.Slide the fixture assembly onto the mounting screws.Tighten decorative nuts removed in step 1 of Installation section securely against fixture base.

Decorative Nut

Mounting Screw

Junction Box

 

3.Install one medium base light bulb (100 Watt maximum).

4.If applicable, place top cover onto fixture and attach using the two decorative nuts (included). Hand tighten only.

5.After completing the tests on page 4, caulk around fixture base with silicone weather sealant.

6.If you will not be installing the optional tail assembly, install the decorative nut onto the bottom of the fixture now.

Optional Assembly

If so equipped, you may install the decorative tail as shown below.

1.Screw hex nut onto bottom of fixture.

2.Screw extension bar into hex nut.

3.Slide tail piece and top trim piece onto exten- sion bar.

4.Slide bottom trim piece (with drain hole) onto extension bar.

5.Install the decorative nut onto extension bar.

Hex Nut

Tail Piece

 

Trim (top)

 

Trim (bottom with

Decorative Nut

hole)

Testing and Adjustments

1.Turn on the circuit breaker and light switch.

Note: Sensor has a 1 1/2 minute warm up period before it will detect motion. When firstturned on wait 1 1/2 minutes.

2.Set:

ON-TIME switch to TEST SENSITIVITY dial to Midway

TEST 1 5 10 MIN

LO - M - HI

ON-TIME

SENSITIVITY

598-1285-00

Page 4
Image 4
Heath Zenith 52-4477-8 operating instructions Final Assembly, Testing and Adjustments, Optional Assembly