Image 6
Maximum Range

150°

6 ft.

(1.8 m) MaximumCoverage Angle

30 ft.

(9.1m)

Maximum Range

Maximum

 

Coverage Angle

Thedetectorislesssensitivetomotiondirectlyto- wards it and more sensitive to across motion.

Motion

Motion

 

 

Sensor

Least Sensitive

Most Sensitive

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head left or right to change the coverage area.

Note: Grasp the sensor only as shown and turn the entire sensor. Any other method may damage the sensor. Do not force it past the stops.

If you need to change the sensitivity, temporarily remove the fixture and make the adjustment.Too much sensitivity may increase false triggering.

Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).

Set the amount of time after dusk you want the lights on accent level.

SPECIFICATIONS

Range . . . . . . Up to 30 ft. (9.1 m) [varieswithsurrounding temperature].

Sensing Angle. . . Up to 150°, 240° adjustable

Electrical Load. . . See rating on fixture for maximum wattage Sensor Capacity . . Up to 360 Watts (3.0

A.) Maximum

Power Requirements 120 VAC, 60 Hz Operating Modes. . TEST, AUTO, and

MANUAL MODE Time Delay . . . . 1, 5, 10 minutes DualBrite® Timer. . 3, 6 hours, dusk-to

dawn

DESA Specialty Products reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

240°

Sensor Aiming

Adjustment Angle

598-1283-00