A

Fibre Channel port specifications

 

 

 

 

TABLE 17

Environmental requirements (Continued)

 

 

 

 

 

 

 

 

 

Condition

 

Acceptable range during operation

Acceptable range during nonoperation

 

 

 

 

 

 

 

 

Airflow

 

250 cu ft/min.

None required

 

 

 

 

(425 cu m/hr)

 

 

 

 

 

 

 

 

Heat dissipation

1195 Watts or 4078 BTU/hr

Not applicable

 

 

(fully loaded with QSFPs)

(192 port configuration)

 

 

 

 

 

 

 

NOTE

The 0° to 40° Celsius range applies to the ambient air temperature at the air intake vents on the nonport side of the Brocade DCX 8510-4.

The temperature inside the Brocade DCX 8510-4 can be up to 75° Celsius during operation. If the internal temperature range exceeds the operating ranges of the components, the LEDs, error messages, and Fabric Watch alerts will indicate a problem. Use the tempShow command or Fabric Watch commands to view temperature status.

Fibre Channel port specifications

The Fibre Channel ports in the Brocade DCX 8510-4 support full duplex link speeds at 2, 4, 8, 10, or 16 Gbps inbound and outbound, automatically negotiating to the highest common speed of all devices connected to the port.

The ports are compatible with optical SWL (short wavelength: approximately 850 nm), optical LWL

(long wavelength: approximately 1310 nm), and optical ELWL (extended long wavelength: approximately 1550 nm) laser transmitter SFPs, SFP+s, mSFPs (FC8-64 only), and XFPs (FC10-6 only). The strength of the signal is determined by the type of SFP, SFP+, mSFP or XFP in use. mSFPs support only SWL.

QSFP ports are fixed speed 16 Gbps ports designed to be used with specialized quad (4x16) connections and cables. They support only SWL.

The ports are universal and self-configuring, capable of becoming F_Ports (fabric ports), FL_Ports (fabric loop-enabled ports), or E_Ports (expansion ports).

The ports meet all required safety standards. For a listing of these standards, see “Regulatory compliance”.

Power specifications

The power subsystem is a redundant +48V DC power distribution system with a provision for up to two 2000-watt, 48V DC bulk power supplies. Two bulk power supplies produce the intermediate distribution voltage in the distributed power system.

If circuits are available, 200-240 VAC (220 VAC nominal) is always recommended as a greener and more efficient alternative.

114

Brocade DCX 8510-4 Backbone Hardware Reference Manual

 

53-1002177-05

Page 134
Image 134
Brocade Communications Systems DCX 8510-4 manual Fibre Channel port specifications, Power specifications