5 Brocade DCX
5.Display and record the manufacturer serial numbers.
Enter chassisShow; then copy the command output into the
“Factory Serial Num” and “Serial Num” are listed under “Chassis/WWN Unit 1.” If the current WWN cards are the original cards, the factory serial number listed is the same as the chassis serial number.
switch:admin> chassisshow
Chassis Backplane Revision: 1F
SW BLADE Slot: 1 |
|
|
|
|
Header Version: | 2 |
|
|
|
Power Consume Factor: |
|
|
| |
Factory Part Num: |
|
| ||
Factory Serial Num: | KP000000195 |
|
| |
Manufacture: | Day: 1 Month: 1 Year: 2007 | |||
Update: | Day: 14 | Month: | 3 | Year: 2012 |
Time Alive: | 187 days |
|
|
|
Time Awake: | 3 days |
|
|
|
<output truncated> |
|
|
|
|
CHASSIS/WWN Unit: 1 | (in same assembly as WWN Unit: 2) | |||
Header Version: | 2 |
|
|
|
Power Consume Factor: |
|
|
| |
Factory Part Num: |
|
| ||
Factory Serial Num: | FT02X805BE2 |
|
| |
Manufacture: | Day: 26 | Month: | 3 | Year: 2007 |
Update: | Day: 14 | Month: | 3 | Year: 2009 |
Time Alive: | 207 days |
|
|
|
Time Awake: | 3 days |
|
|
|
<output truncated>
switch:admin>
6.Create a SAN “profile” by entering and recording the information provided by the following commands:
•nsShow
•nsAllShow
•switchShow -qsfp
•fabricShow
Copy the command output into a text file named “SANbefor.txt.” After the Brocade DCX
switch:admin> nsshow
Enter Pid COS PortName NodeName TTL <output truncated>
switch:admin> nsallshow
12Nx_Ports in the Fabric <output truncated>
switch:admin> switchshow
98 | Brocade DCX |
|