5 |
NOTE
The QSFP ports can be used only with an
NOTE
For the Brocade 8510 Backbones, an
ATTENTION
For the 8510 series models, if the QSFP cables are not used, make sure the rubber gaskets are in the QSFP transceivers.
Table 10 describes the connector port LED patterns and the recommended actions for those patterns.
TABLE 10 | QSFP connector port LEDs |
|
| |
|
|
|
|
|
LED purpose |
| Color | Status | Recommended action |
|
|
|
|
|
QSFP |
| No light (LED is off) | No QSFP module, all four | No action required if QSFP no |
connector |
|
| QSFP ports are disabled | present or |
status |
|
|
| verify that the QSFP is fully inserted. |
|
|
|
|
|
|
| Steady amber | QSFP module is in, all four | No action required if QSFP only is |
|
|
| ports have no signal/no | installed or |
|
|
| sync. | ensure that the cable is properly |
|
|
|
| connected. If the LED remains |
|
|
|
| amber, consult the Brocade DCX |
|
|
|
|
Blinking amber | Port is disabled or faulted, |
| FC link activity, segmented, |
| loopback mode, also |
| during transition between |
| QSFP cable insertion and |
| confirmation. |
Check for console messages or wait for all four ports to come online.
Steady green | Both ends of QSFP cable | No action required. |
| are in and all ports are |
|
| online. Full link is |
|
| established. |
|
|
|
|
Follow this procedure to install the QSFP cables. Refer to the Fabric OS Administrator’s Guide for the configuration procedure and requirements.
Figure 31 shows an QSFP cable and transceiver. The QSFP connectors on the core blades are labeled by trunk group (trunking is optional) for ease of installation. The subsequent figures shows acceptable cabling configurations for the ICL feature. The recommended topology is the parallel type where there are four QSFP cables connected between any pair of Brocade 8510 series chassis.The full mesh configuration is also supported.
Brocade DCX | 89 |
|