Inter-chassis link (QSFP) cable removal and replacement

5

NOTE

The QSFP ports can be used only with an inter-chassis link (ICL) license. After the addition or removal of a license, the license enforcement is performed on the ports only when the portdisable and portenable commands are issued on the ports. An ICL license must be installed on all Brocade Backbones forming the ICL connection. Beginning with Fabric OS v7.0.1, up to nine neighboring Brocade 8510 series chassis can be connected with the QSFP cables. Under Fabric OS v7.0.0, six chassis can be connected.

NOTE

For the Brocade 8510 Backbones, an off-the-shelf QSFP cable up to 50 meters long can be used as an ICL cable.

ATTENTION

For the 8510 series models, if the QSFP cables are not used, make sure the rubber gaskets are in the QSFP transceivers.

Table 10 describes the connector port LED patterns and the recommended actions for those patterns.

TABLE 10

QSFP connector port LEDs

 

 

 

 

 

 

 

LED purpose

 

Color

Status

Recommended action

 

 

 

 

 

QSFP

 

No light (LED is off)

No QSFP module, all four

No action required if QSFP no

connector

 

 

QSFP ports are disabled

present or

status

 

 

 

verify that the QSFP is fully inserted.

 

 

 

 

 

 

 

Steady amber

QSFP module is in, all four

No action required if QSFP only is

 

 

 

ports have no signal/no

installed or

 

 

 

sync.

ensure that the cable is properly

 

 

 

 

connected. If the LED remains

 

 

 

 

amber, consult the Brocade DCX

 

 

 

 

8510-4 supplier.

Blinking amber

Port is disabled or faulted,

 

FC link activity, segmented,

 

loopback mode, also

 

during transition between

 

QSFP cable insertion and

 

confirmation.

Check for console messages or wait for all four ports to come online.

Steady green

Both ends of QSFP cable

No action required.

 

are in and all ports are

 

 

online. Full link is

 

 

established.

 

 

 

 

Follow this procedure to install the QSFP cables. Refer to the Fabric OS Administrator’s Guide for the configuration procedure and requirements.

Figure 31 shows an QSFP cable and transceiver. The QSFP connectors on the core blades are labeled by trunk group (trunking is optional) for ease of installation. The subsequent figures shows acceptable cabling configurations for the ICL feature. The recommended topology is the parallel type where there are four QSFP cables connected between any pair of Brocade 8510 series chassis.The full mesh configuration is also supported.

Brocade DCX 8510-4 Backbone Hardware Reference Manual

89

53-1002177-05

 

Page 109
Image 109