Diagnostics C
•Review the system error log using the errShow or errDump commands.
Any errors detected during POST are written to the system log, which is accessible through the errShow command. For information about error messages, refer to the Fabric OS Message Reference.
POST includes the following steps:
1.Preliminary POST diagnostics are run.
2.Operating system is initialized.
3.Hardware is initialized.
4.Diagnostic tests are run on several functions, including circuitry, port functionality, ability to send and receive frames, all aspects of memory, parity, statistics counters, and serialization.
Boot
In addition to POST, boot includes the following steps after POST is complete:
1.Universal port configuration is performed.
2.Links are initialized.
3.Fabric is analyzed. If any ports are connected to other switches, the Brocade DCX
4.The Brocade DCX
5.Unicast routing tables are constructed.
6.Normal port operation is enabled.
Diagnostics
Diagnostic tests are automatically run during POST to check the status of the Brocade DCX
Diagnostic tests can also be run manually to test and troubleshoot the hardware and the firmware, including internal connections and circuitry, transceivers, and port cables. However, diagnostic tests are generally intended for use by support personnel.
NOTE
Error messages do not necessarily indicate that the Brocade DCX
Each diagnostic test can be implemented by entering the related command through a Telnet or serial session. For a list of diagnostic tests and commands, refer to the Fabric OS Administrator’s Guide.
Brocade DCX | 135 |
|