5 Control processor blade (CP8) removal and replacement

firmware

firmwareKey

support

The firmware folder contains the folder for the specific release you are installing.

1.Insert the USB device into the active CP blade.

2.Attach a serial cable from the PC to the active CP blade.

3.Log in to the active CP blade as admin if you are not still logged in and enter usbStorage -eto enable the USB device.

4.Remove the serial cable from the active CP blade and attach it to the standby CP blade and log in as admin.

5.Run firmwareDownload -sto download the firmware to the standby CP blade. The -soption also disables the autoreboot, so you will have to manually issue a reboot after the download finishes to initiate firmwarecommit. Enter all requested information (use default values).

6.This does not apply to the DCX 8510 models.When the download process finishes, run firmwareDownloadStatus to verify that the firmware has been updated. The command displays a running account of the progress of the firmwareDownload command until the command has completed. The final message is similar to the following and will appear with a date and time stamp:

Slot 4 (CP0, active): Firmwaredownload command has completed successfully. Use firmwareshow to verify the firmware versions.

7.Ensure that you are still logged in to the standby CP blade (the blade for which you just changed the firmware level) and type reboot. The reboot of the standby CP will initiate a firmwarecommit to the secondary partition and log you out.

DCX_124:admin> reboot

Broadcast message from root (ttyS0) Fri Jun 18 14:49:45 2010...

The system is going down for reboot NOW !! INIT: Switching to runlevel: 6

INIT: Sending processes the TERM signal DCX_124:admin> HAMu Heartbeat down, stop FSS

Unmounting all f##exiting due to signal: 9, pending signals: 0x20000, 0x0

ilesystems.

Please stand by while rebooting the system...

Restarting system.

The system is coming up, please wait...

.

.

.

Fri Jun 18 14:53:13 2010: Doing firmwarecommit now. Please wait ...

Fri Jun 18 14:55:27 2010: Firmware commit completes successfully. Validating the filesystem ...

Fri Jun 18 22:36:05 2010: Doing firmwarecommit now. Please wait ...

Fri Jun 18 22:36:48 2010: Firmware commit completes successfully. 2010/06/18-14:56:50, [SULB-1004], 908, SLOT 7 CHASSIS, INFO, Brocade_DCX, Firmwarecommit has completed.

2010/06/18-14:56:50, [SULB-1036], 909, SLOT 7 CHASSIS, INFO, Brocade_DCX, The new Version: Fabric OS v6.3.0c

74

Brocade DCX 8510-4 Backbone Hardware Reference Manual

 

53-1002177-05

Page 94
Image 94
Brocade Communications Systems manual Brocade DCX 8510-4 Backbone Hardware Reference Manual