Determining the status of a WWN card | 4 |
1 2
1 Power LED | 2 Fault LED |
FIGURE 16 Blower assembly
Table 7 describes the LED patterns for the blower assembly.
TABLE 7 | Blower assembly LED descriptions |
| ||
|
|
|
|
|
LED purpose |
| Color | Status | Recommended action |
|
|
|
|
|
Power |
| No light | Blower assembly does not | Ensure that the blower assembly |
|
| (LED is off) | have power. | is firmly seated and has power. |
|
|
|
|
|
|
| Steady green | Blower assembly has | No action required. |
|
|
| power. |
|
Fault | No light | Blower assembly is either |
| (LED is off) | healthy or does not have |
|
| power. |
Ensure that the blower assembly has power.
| Steady amber | Blower assembly has a | Replace the blower assembly. |
|
| failure (full or partial). |
|
|
|
|
|
| Blower assembly is not | Pull the unit out and reseat it. If | |
| (on 2 sec, then off 2 sec) | seated correctly or is | the LED continues to flash, |
|
| faulty. | replace the unit. |
|
|
|
|
| Flashing amber | Fan is disabled. | Run the fanEnable command to |
| (on 1/2 sec, then off 3.5 sec) |
| enable the fan. |
|
|
|
|
| Environmental range | Check for | |
| (on 1/2 sec, then off 1/2 sec) | exceeded. | environmental condition, resolve |
|
|
| any problems, and reseat the |
|
|
| unit. If the LED continues to flash, |
|
|
| replace the unit. |
|
|
|
|
Determining the status of a WWN card
Complete the following steps to determine the status of a WWN card.
Brocade DCX | 55 |
|