Brocade DCX 8510-4 Backbone Hardware Reference Manual 77
53-1002177-05
Core switch blade (CR16-4) removal and replacement 5
For more information about error messages, refer to the Fabric OS Message Reference.
Removing a core switch blade (CR16-4)
The Brocade DCX 8510-4 continues to operate while a core switch blade is being replaced. Refer to
Figure 23 for the followi ng procedure .
Complete the following steps to remove the core switch blade.
ATTENTION
Follow ESD prec autions.
NOTE
The CR16-4 blade is compatible only with the Brocade DCX 8510-4.
1. Remove the chassis door.
2. Unscrew the two thumb screws from the ejectors on the blade using the Phillips screwdriver.
Unscrew the left thumb screw until it pops out. This initiates a hot-swap request.
3. Label and then disconnect cables from the faulty core switch blade.
4. Open the ejectors by rotating them toward the center of the blade face. Pull the blade out of
the chassis using the ejectors.