Blade filler panel removal and replacement | 5 |
•For
3.Perform the appropriate following action based on the type of blade:
•For
4.Perform the appropriate following action based on the type of blade:
•For
5.Verify that the power LED on the port blade is displaying a steady green light. If it does not turn on, ensure that the blade is firmly seated.
6.The Status LED on the blade will show amber until POST completes for the blade. It should then display green. If it remains amber, the board may not be properly seated in the backplane or the board may be faulty.
7.Install the transceivers and cables in the blade. For mSFP
8.Group and route the cables through the vertical cable management fingers.
9.Replace the chassis door.
Blade filler panel removal and replacement
This section describes how to remove and replace blade filler panels. Refer to Figure 21 for this procedure.
NOTE
Some filler panels have two thumbscrews and some have only one. Be sure to unscrew or tighten both if you are using the
Removing a filler panel
Complete the following steps to remove a filler panel from the chassis.
ATTENTION
A filler panel should be removed only when being replaced with a port, application, or encryption blade, or new filler panel. Any slot that is not occupied by a blade should be occupied by a filler panel to ensure correct cooling of the chassis and protection from dust.
1.Remove the chassis door.
2.Unscrew the thumbscrews on the panel using the Phillips screwdriver.
3.Using the tabs, pull the filler panel out of the chassis.
Brocade DCX | 65 |
|