4 Determining the status of a blower assembly

1 Power LED

FIGURE 15 Power supply

Table 6 describes the power supply LED patterns and the recommended actions for those patterns.

TABLE 6 Power supply LED descriptions

LED purpose

Color

Status

Recommended action

Power

No light

Power supply does not have

 

(LED is off)

incoming power and is not

 

 

providing power to the Brocade

 

 

DCX 8510-4.

Ensure that the power supply is firmly seated, the Brocade DCX 8510-4 has incoming power, both power cables are connected, and AC power switches are on.

 

Steady green

Power supply has incoming

No action required.

 

 

power and is providing power to

 

 

 

the Brocade DCX 8510-4.

 

 

 

 

 

 

Flashing green

Power supply is about to fail.

Replace the power supply.

 

 

 

 

Determining the status of a blower assembly

Complete the following steps to determine the status of a blower assembly.

1.Check the LED indicators on the blower assembly (see the following figure). The LED patterns may temporarily change during POST and other diagnostic tests; for information about how to interpret the LED patterns, refer to Table 7. The Brocade DCX 8510-4 has two blowers. Be sure to check each module.

2.Check the blower assembly status using the fanShow command.

The status for each blower assembly displays OK, Absent, or Faulty. The RPM of each fan in the assembly is also provided. If a blower assembly displays absent or faulty, contact the Brocade DCX 8510-4 supplier to order replacement parts. Both physically absent or faulty could also be the result of the power supply not being properly seated.

Figure 16 shows the blower assembly.

54

Brocade DCX 8510-4 Backbone Hardware Reference Manual

 

53-1002177-05

Page 74